Comparison of iodophor and alcohol pledgets with the Medi-Flex blood culture prep kit II for preventing contamination of blood cultures.
Publication
, Journal Article
Wilson, ML; Weinstein, MP; Mirrett, S; Reimer, LG; Fernando, C; Meredith, FT; Reller, LB
Published in: J Clin Microbiol
December 2000
Iodophor and alcohol pledgets were compared with the Medi-Flex Prep Kit II for skin disinfection before venipuncture. Of 12,367 blood cultures collected, 6,362 were done with conventional pledgets and 6, 005 were done with Medi-Flex kits. Contamination occurred in 351 of 6,362 blood cultures (5.5%; range, 3.7 to 8.1%) with conventional pledgets versus 328 of 6,005 (5.5%; range, 3.5 to 7.5%) with Medi-Flex kits.
Duke Scholars
Published In
J Clin Microbiol
DOI
ISSN
0095-1137
Publication Date
December 2000
Volume
38
Issue
12
Start / End Page
4665 / 4667
Location
United States
Related Subject Headings
- Skin
- Reagent Kits, Diagnostic
- Microbiology
- Iodophors
- Humans
- Ethanol
- Disinfection
- Bacteria
- Bacteremia
- 3207 Medical microbiology
Citation
APA
Chicago
ICMJE
MLA
NLM
Wilson, M. L., Weinstein, M. P., Mirrett, S., Reimer, L. G., Fernando, C., Meredith, F. T., & Reller, L. B. (2000). Comparison of iodophor and alcohol pledgets with the Medi-Flex blood culture prep kit II for preventing contamination of blood cultures. J Clin Microbiol, 38(12), 4665–4667. https://doi.org/10.1128/JCM.38.12.4665-4667.2000
Wilson, M. L., M. P. Weinstein, S. Mirrett, L. G. Reimer, C. Fernando, F. T. Meredith, and L. B. Reller. “Comparison of iodophor and alcohol pledgets with the Medi-Flex blood culture prep kit II for preventing contamination of blood cultures.” J Clin Microbiol 38, no. 12 (December 2000): 4665–67. https://doi.org/10.1128/JCM.38.12.4665-4667.2000.
Wilson ML, Weinstein MP, Mirrett S, Reimer LG, Fernando C, Meredith FT, et al. Comparison of iodophor and alcohol pledgets with the Medi-Flex blood culture prep kit II for preventing contamination of blood cultures. J Clin Microbiol. 2000 Dec;38(12):4665–7.
Wilson, M. L., et al. “Comparison of iodophor and alcohol pledgets with the Medi-Flex blood culture prep kit II for preventing contamination of blood cultures.” J Clin Microbiol, vol. 38, no. 12, Dec. 2000, pp. 4665–67. Pubmed, doi:10.1128/JCM.38.12.4665-4667.2000.
Wilson ML, Weinstein MP, Mirrett S, Reimer LG, Fernando C, Meredith FT, Reller LB. Comparison of iodophor and alcohol pledgets with the Medi-Flex blood culture prep kit II for preventing contamination of blood cultures. J Clin Microbiol. 2000 Dec;38(12):4665–4667.
Published In
J Clin Microbiol
DOI
ISSN
0095-1137
Publication Date
December 2000
Volume
38
Issue
12
Start / End Page
4665 / 4667
Location
United States
Related Subject Headings
- Skin
- Reagent Kits, Diagnostic
- Microbiology
- Iodophors
- Humans
- Ethanol
- Disinfection
- Bacteria
- Bacteremia
- 3207 Medical microbiology