Skip to main content
Journal cover image

Three-dimensional MRI microscopy of the normal rat brain.

Publication ,  Journal Article
Johnson, GA; Thompson, MB; Drayer, BP
Published in: Magn Reson Med
April 1987

Magnetic resonance imaging techniques have been developed to enable imaging of the live rat brain with thin (1.2-mm) slices and microscopic pixels (115 X 115 microns). Signal-to-noise ratios high enough to realize the microscopic resolution are obtained with rf coils designed for the subject and through the use of three-dimensional Fourier spin warp imaging. The technique yields 16 contiguous slices. Correlation with fixed pathologic specimens enables unequivocal identification of gray and white matter structures in the brain of a live 200-g rat. Structures clearly visible in the MR images include Ammon's horn, the hypothalamus, corpus callosum and substantia nigra, as well as a number of brainstem nuclei.

Duke Scholars

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

April 1987

Volume

4

Issue

4

Start / End Page

351 / 365

Location

United States

Related Subject Headings

  • Rats
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Spectroscopy
  • Cricetinae
  • Brain
  • Animals
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Johnson, G. A., Thompson, M. B., & Drayer, B. P. (1987). Three-dimensional MRI microscopy of the normal rat brain. Magn Reson Med, 4(4), 351–365. https://doi.org/10.1002/mrm.1910040406
Johnson, G. A., M. B. Thompson, and B. P. Drayer. “Three-dimensional MRI microscopy of the normal rat brain.Magn Reson Med 4, no. 4 (April 1987): 351–65. https://doi.org/10.1002/mrm.1910040406.
Johnson GA, Thompson MB, Drayer BP. Three-dimensional MRI microscopy of the normal rat brain. Magn Reson Med. 1987 Apr;4(4):351–65.
Johnson, G. A., et al. “Three-dimensional MRI microscopy of the normal rat brain.Magn Reson Med, vol. 4, no. 4, Apr. 1987, pp. 351–65. Pubmed, doi:10.1002/mrm.1910040406.
Johnson GA, Thompson MB, Drayer BP. Three-dimensional MRI microscopy of the normal rat brain. Magn Reson Med. 1987 Apr;4(4):351–365.
Journal cover image

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

April 1987

Volume

4

Issue

4

Start / End Page

351 / 365

Location

United States

Related Subject Headings

  • Rats
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Spectroscopy
  • Cricetinae
  • Brain
  • Animals
  • 4003 Biomedical engineering