Skip to main content

Signal-to-noise improvements in three-dimensional NMR microscopy using limited-angle excitation

Publication ,  Journal Article
Karis, JP; Allan Johnson, G; Glover, GH
Published in: Journal of Magnetic Resonance (1969)
January 1, 1987

The 3D FT variant of spin-echo imaging has previously been successfully used to yield images at microscopic resolution. In obtaining such high resolution, optimization of signal to noise for a given acquisition time is crucial. Using a limited-angle (<60) slice-selective pulse one can improve the effective signal to noise or reduce the experimental time. The spin echo is generated through gradient refocusing. A phantom with T1 of 800 and 1200 ms was used to simulate white and gray matter. Signal intensity was modeled by the expression M= M0sinθ[1-exp(- TR T1)] 1-exp(- TR T1)cosθ For TR < 200 ms, limited-angle excitation can yield improvements in signal to noise by greater than a factor of two. These results were experimentally verified on a 1.5 T prototype system (General Electric, Milwaukee, Wis.) configured with gradient and rf coils designed for NMR microscopy. In those cases where signal-to-noise concerns do not require signal averaging beyond that which is inherent in the 3D FT technique, the limited-angle approach can reduce the acquisition time by as much as a factor of four. These results were verified in small animal studies of the brain of a 200 g rat. © 1987.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Journal of Magnetic Resonance (1969)

DOI

ISSN

0022-2364

Publication Date

January 1, 1987

Volume

71

Issue

1

Start / End Page

24 / 33
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Karis, J. P., Allan Johnson, G., & Glover, G. H. (1987). Signal-to-noise improvements in three-dimensional NMR microscopy using limited-angle excitation. Journal of Magnetic Resonance (1969), 71(1), 24–33. https://doi.org/10.1016/0022-2364(87)90124-7
Karis, J. P., G. Allan Johnson, and G. H. Glover. “Signal-to-noise improvements in three-dimensional NMR microscopy using limited-angle excitation.” Journal of Magnetic Resonance (1969) 71, no. 1 (January 1, 1987): 24–33. https://doi.org/10.1016/0022-2364(87)90124-7.
Karis JP, Allan Johnson G, Glover GH. Signal-to-noise improvements in three-dimensional NMR microscopy using limited-angle excitation. Journal of Magnetic Resonance (1969). 1987 Jan 1;71(1):24–33.
Karis, J. P., et al. “Signal-to-noise improvements in three-dimensional NMR microscopy using limited-angle excitation.” Journal of Magnetic Resonance (1969), vol. 71, no. 1, Jan. 1987, pp. 24–33. Scopus, doi:10.1016/0022-2364(87)90124-7.
Karis JP, Allan Johnson G, Glover GH. Signal-to-noise improvements in three-dimensional NMR microscopy using limited-angle excitation. Journal of Magnetic Resonance (1969). 1987 Jan 1;71(1):24–33.

Published In

Journal of Magnetic Resonance (1969)

DOI

ISSN

0022-2364

Publication Date

January 1, 1987

Volume

71

Issue

1

Start / End Page

24 / 33