Skip to main content
Journal cover image

MRI of the lungs using hyperpolarized noble gases.

Publication ,  Journal Article
Möller, HE; Chen, XJ; Saam, B; Hagspiel, KD; Johnson, GA; Altes, TA; de Lange, EE; Kauczor, H-U
Published in: Magn Reson Med
June 2002

The nuclear spin polarization of the noble gas isotopes (3)He and (129)Xe can be increased using optical pumping methods by four to five orders of magnitude. This extraordinary gain in polarization translates directly into a gain in signal strength for MRI. The new technology of hyperpolarized (HP) gas MRI holds enormous potential for enhancing sensitivity and contrast in pulmonary imaging. This review outlines the physics underlying the optical pumping process, imaging strategies coping with the nonequilibrium polarization, and effects of the alveolar microstructure on relaxation and diffusion of the noble gases. It presents recent progress in HP gas MRI and applications ranging from MR microscopy of airspaces to imaging pulmonary function in patients and suggests potential directions for future developments.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

June 2002

Volume

47

Issue

6

Start / End Page

1029 / 1051

Location

United States

Related Subject Headings

  • Xenon Radioisotopes
  • Pulmonary Gas Exchange
  • Nuclear Medicine & Medical Imaging
  • Noble Gases
  • Magnetic Resonance Imaging
  • Lung Diseases
  • Lung
  • Humans
  • Helium
  • Forecasting
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Möller, H. E., Chen, X. J., Saam, B., Hagspiel, K. D., Johnson, G. A., Altes, T. A., … Kauczor, H.-U. (2002). MRI of the lungs using hyperpolarized noble gases. Magn Reson Med, 47(6), 1029–1051. https://doi.org/10.1002/mrm.10173
Möller, Harald E., X Josette Chen, Brian Saam, Klaus D. Hagspiel, G Allan Johnson, Talissa A. Altes, Eduard E. de Lange, and Hans-Ulrich Kauczor. “MRI of the lungs using hyperpolarized noble gases.Magn Reson Med 47, no. 6 (June 2002): 1029–51. https://doi.org/10.1002/mrm.10173.
Möller HE, Chen XJ, Saam B, Hagspiel KD, Johnson GA, Altes TA, et al. MRI of the lungs using hyperpolarized noble gases. Magn Reson Med. 2002 Jun;47(6):1029–51.
Möller, Harald E., et al. “MRI of the lungs using hyperpolarized noble gases.Magn Reson Med, vol. 47, no. 6, June 2002, pp. 1029–51. Pubmed, doi:10.1002/mrm.10173.
Möller HE, Chen XJ, Saam B, Hagspiel KD, Johnson GA, Altes TA, de Lange EE, Kauczor H-U. MRI of the lungs using hyperpolarized noble gases. Magn Reson Med. 2002 Jun;47(6):1029–1051.
Journal cover image

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

June 2002

Volume

47

Issue

6

Start / End Page

1029 / 1051

Location

United States

Related Subject Headings

  • Xenon Radioisotopes
  • Pulmonary Gas Exchange
  • Nuclear Medicine & Medical Imaging
  • Noble Gases
  • Magnetic Resonance Imaging
  • Lung Diseases
  • Lung
  • Humans
  • Helium
  • Forecasting