Skip to main content
Journal cover image

Surface coil imaging of rat spine at 7.0 T.

Publication ,  Journal Article
Banson, ML; Cofer, GP; Hedlund, LW; Johnson, GA
Published in: Magn Reson Imaging
1992

An inductively coupled surface coil for imaging the rat spine at 7 T is described. This planar circular probe was made from microwave substrate to limit the size of the coil and to minimize the magnetic susceptibility. The surface coil was used as a single transmit/receive coil and as a receive-only coil with a birdcage body coil for excitation. The signal-to-noise ratio (SNR) of the probe was compared to a 5-cm birdcage coil and exceeded the birdcage coil's SNR by three to six times at superficial structures. The main advantages of the probe are an improved SNR for superficial structures and a simple design and use. Images with 50 x 50 x 500 micron voxels were obtained of the rat spine with excellent anatomical detail.

Duke Scholars

Published In

Magn Reson Imaging

DOI

ISSN

0730-725X

Publication Date

1992

Volume

10

Issue

6

Start / End Page

929 / 934

Location

Netherlands

Related Subject Headings

  • Spine
  • Rats, Sprague-Dawley
  • Rats
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Equipment Design
  • Animals
  • 3202 Clinical sciences
  • 1702 Cognitive Sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Banson, M. L., Cofer, G. P., Hedlund, L. W., & Johnson, G. A. (1992). Surface coil imaging of rat spine at 7.0 T. Magn Reson Imaging, 10(6), 929–934. https://doi.org/10.1016/0730-725x(92)90447-8
Banson, M. L., G. P. Cofer, L. W. Hedlund, and G. A. Johnson. “Surface coil imaging of rat spine at 7.0 T.Magn Reson Imaging 10, no. 6 (1992): 929–34. https://doi.org/10.1016/0730-725x(92)90447-8.
Banson ML, Cofer GP, Hedlund LW, Johnson GA. Surface coil imaging of rat spine at 7.0 T. Magn Reson Imaging. 1992;10(6):929–34.
Banson, M. L., et al. “Surface coil imaging of rat spine at 7.0 T.Magn Reson Imaging, vol. 10, no. 6, 1992, pp. 929–34. Pubmed, doi:10.1016/0730-725x(92)90447-8.
Banson ML, Cofer GP, Hedlund LW, Johnson GA. Surface coil imaging of rat spine at 7.0 T. Magn Reson Imaging. 1992;10(6):929–934.
Journal cover image

Published In

Magn Reson Imaging

DOI

ISSN

0730-725X

Publication Date

1992

Volume

10

Issue

6

Start / End Page

929 / 934

Location

Netherlands

Related Subject Headings

  • Spine
  • Rats, Sprague-Dawley
  • Rats
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Equipment Design
  • Animals
  • 3202 Clinical sciences
  • 1702 Cognitive Sciences
  • 1103 Clinical Sciences