A simple preparation for obtaining a reliable heart rate record in freely moving rats

Publication ,  Journal Article
Sherwood, A
Published in: Behavior Research Methods & Instrumentation
November 1, 1981

A technique for recording heart rate (HR) from freely moving rats using a specially developed harness and subdermal electrodes is described. Electrodes are implanted via a hypodermic needle. Animals prepared in this way are unrestricted in their behavior and show no signs of distress. EKG signals are of high fidelity and are relatively free of electromyographic interference. These characteristics enable reliable phasic HR responses to be recorded during periods of high skeletal muscle activity such as those exhibited during aversive conditioning. Since the procedure is relatively untraumatic, electrodes may be removed and reimplanted at a later date. © 1981 Psychonomic Society, Inc.

Duke Scholars

Published In

Behavior Research Methods & Instrumentation

DOI

EISSN

1554-3528

ISSN

1554-351X

Publication Date

November 1, 1981

Volume

13

Issue

6

Start / End Page

763 / 765

Related Subject Headings

  • Experimental Psychology
  • 5204 Cognitive and computational psychology
  • 5202 Biological psychology
  • 4905 Statistics
  • 1702 Cognitive Sciences
  • 1701 Psychology
  • 0801 Artificial Intelligence and Image Processing
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Sherwood, A. (1981). A simple preparation for obtaining a reliable heart rate record in freely moving rats. Behavior Research Methods & Instrumentation, 13(6), 763–765. https://doi.org/10.3758/BF03207968
Sherwood, A. “A simple preparation for obtaining a reliable heart rate record in freely moving rats.” Behavior Research Methods & Instrumentation 13, no. 6 (November 1, 1981): 763–65. https://doi.org/10.3758/BF03207968.
Sherwood A. A simple preparation for obtaining a reliable heart rate record in freely moving rats. Behavior Research Methods & Instrumentation. 1981 Nov 1;13(6):763–5.
Sherwood, A. “A simple preparation for obtaining a reliable heart rate record in freely moving rats.” Behavior Research Methods & Instrumentation, vol. 13, no. 6, Nov. 1981, pp. 763–65. Scopus, doi:10.3758/BF03207968.
Sherwood A. A simple preparation for obtaining a reliable heart rate record in freely moving rats. Behavior Research Methods & Instrumentation. 1981 Nov 1;13(6):763–765.
Journal cover image

Published In

Behavior Research Methods & Instrumentation

DOI

EISSN

1554-3528

ISSN

1554-351X

Publication Date

November 1, 1981

Volume

13

Issue

6

Start / End Page

763 / 765

Related Subject Headings

  • Experimental Psychology
  • 5204 Cognitive and computational psychology
  • 5202 Biological psychology
  • 4905 Statistics
  • 1702 Cognitive Sciences
  • 1701 Psychology
  • 0801 Artificial Intelligence and Image Processing