Skip to main content

Breast tumour imaging using incomplete circular orbit pinhole SPET: a phantom study.

Publication ,  Journal Article
Scarfone, C; Jaszczak, RJ; Li, J; Soo, MS; Smith, MF; Greer, KL; Coleman, RE
Published in: Nucl Med Commun
November 1997

Improvements in 99Tcm-sestamibi breast lesion visualization using single photon emission tomography (SPET) may help define the clinical role of this technique alongside X-ray mammography in the diagnosis and management of breast cancer. Pinhole SPET offers the advantages of high resolution and sensitivity when compared to conventional parallel-beam collimation for sources located near the pinhole aperture. In this work, the potential of incomplete (180 degrees) circular orbit (ICO) SPET with pinhole collimation is investigated as a means to visualize small (6.4 and 9.6 mm diameter) spherical simulated tumours, at clinical count densities and tumour-to-background ratios, in a breast phantom. ICO pinhole SPET is compared to complete circular orbit (CCO) pinhole SPET for reference, and planar breast imaging (scintimammography) using parallel-beam and pinhole collimators. A prototype box-shaped pinhole collimator with a 4 mm diameter circular aperture was used to acquire projections of an 890 ml breast phantom both in isolation and mounted on a cylinder filled with a mixture of 99Tcm-pertechnetate and water. A heart phantom containing 99Tcm activity in the myocardium was placed in the cylinder. Simulated tumours containing 99Tcm were placed in the breast phantom and scanned at clinically relevant count densities and scan times with tumour-to-normal tissue concentration ratios of 5.0:1 (9.6 mm sphere) and 7.7:1 (6.4 mm sphere). Phantom data were reconstructed using pinhole filtered backprojection (FBP) and maximum likelihood-expectation maximization (ML-EM). The tumours were not visualized with scintimammography, in which lesion contrast and signal-to-noise were estimated from region of interest analysis to be < 2% and 0.01, respectively. Average (over lesion size and scan time) contrast and signal-to-noise in the ICO (CCO) SPET images were 33% and 1.72 (34% and 1.3), respectively. These values indicate that ICO pinhole SPET has the potential to improve visualization of small (< 10 mm) breast tumours when compared with scintimammography, which may be beneficial for the early classification of cancers of the breast.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Nucl Med Commun

DOI

ISSN

0143-3636

Publication Date

November 1997

Volume

18

Issue

11

Start / End Page

1077 / 1086

Location

England

Related Subject Headings

  • Tomography, Emission-Computed, Single-Photon
  • Technetium Tc 99m Sestamibi
  • Radiopharmaceuticals
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Models, Anatomic
  • Mammography
  • Humans
  • Female
  • Equipment Design
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Scarfone, C., Jaszczak, R. J., Li, J., Soo, M. S., Smith, M. F., Greer, K. L., & Coleman, R. E. (1997). Breast tumour imaging using incomplete circular orbit pinhole SPET: a phantom study. Nucl Med Commun, 18(11), 1077–1086. https://doi.org/10.1097/00006231-199711000-00012
Scarfone, C., R. J. Jaszczak, J. Li, M. S. Soo, M. F. Smith, K. L. Greer, and R. E. Coleman. “Breast tumour imaging using incomplete circular orbit pinhole SPET: a phantom study.Nucl Med Commun 18, no. 11 (November 1997): 1077–86. https://doi.org/10.1097/00006231-199711000-00012.
Scarfone C, Jaszczak RJ, Li J, Soo MS, Smith MF, Greer KL, et al. Breast tumour imaging using incomplete circular orbit pinhole SPET: a phantom study. Nucl Med Commun. 1997 Nov;18(11):1077–86.
Scarfone, C., et al. “Breast tumour imaging using incomplete circular orbit pinhole SPET: a phantom study.Nucl Med Commun, vol. 18, no. 11, Nov. 1997, pp. 1077–86. Pubmed, doi:10.1097/00006231-199711000-00012.
Scarfone C, Jaszczak RJ, Li J, Soo MS, Smith MF, Greer KL, Coleman RE. Breast tumour imaging using incomplete circular orbit pinhole SPET: a phantom study. Nucl Med Commun. 1997 Nov;18(11):1077–1086.

Published In

Nucl Med Commun

DOI

ISSN

0143-3636

Publication Date

November 1997

Volume

18

Issue

11

Start / End Page

1077 / 1086

Location

England

Related Subject Headings

  • Tomography, Emission-Computed, Single-Photon
  • Technetium Tc 99m Sestamibi
  • Radiopharmaceuticals
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Models, Anatomic
  • Mammography
  • Humans
  • Female
  • Equipment Design