Skip to main content
Journal cover image

An auto-anti-M causing hemolysis in vitro.

Publication ,  Journal Article
Combs, MR; O'Rourke, MM; Issitt, PD; Telen, MJ
Published in: Transfusion
October 1991

A 64-year-old white man, who had never received a transfusion, was found to have anti-M in his serum. The antibody agglutinated all M+ red cells in room-temperature tests. When the ionic strength of the test milieu was reduced by use of an additive solution and the tests were incubated at 37 degrees C, the antibody hemolyzed M + N- but not M+N+ red cells. All M+ red cells reacted in indirect antiglobulin tests using polyspecific antiglobulin reagents when such tests followed an initial incubation at room temperature. When red cells and the patient's serum were warmed to 37 degrees C before being mixed, no antibody activity was demonstrable. The antibody was adsorbed to exhaustion onto M+N- and M+N+ red cells (including the patient's own), and its activity was destroyed by dithiothreitol. There was no evidence of in vivo red cell destruction by the autoantibody. No previously reported example of anti-M has been shown to activate complement in conventional in vitro tests. This example was extraordinary in that it caused sufficient complement activation to present as an in vitro hemolysin.

Duke Scholars

Published In

Transfusion

DOI

ISSN

0041-1132

Publication Date

October 1991

Volume

31

Issue

8

Start / End Page

756 / 758

Location

United States

Related Subject Headings

  • Temperature
  • Middle Aged
  • Male
  • MNSs Blood-Group System
  • Humans
  • Hemolysis
  • Complement Activation
  • Cardiovascular System & Hematology
  • Autoantibodies
  • Antibody Specificity
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Combs, M. R., O’Rourke, M. M., Issitt, P. D., & Telen, M. J. (1991). An auto-anti-M causing hemolysis in vitro. Transfusion, 31(8), 756–758. https://doi.org/10.1046/j.1537-2995.1991.31892023504.x
Combs, M. R., M. M. O’Rourke, P. D. Issitt, and M. J. Telen. “An auto-anti-M causing hemolysis in vitro.Transfusion 31, no. 8 (October 1991): 756–58. https://doi.org/10.1046/j.1537-2995.1991.31892023504.x.
Combs MR, O’Rourke MM, Issitt PD, Telen MJ. An auto-anti-M causing hemolysis in vitro. Transfusion. 1991 Oct;31(8):756–8.
Combs, M. R., et al. “An auto-anti-M causing hemolysis in vitro.Transfusion, vol. 31, no. 8, Oct. 1991, pp. 756–58. Pubmed, doi:10.1046/j.1537-2995.1991.31892023504.x.
Combs MR, O’Rourke MM, Issitt PD, Telen MJ. An auto-anti-M causing hemolysis in vitro. Transfusion. 1991 Oct;31(8):756–758.
Journal cover image

Published In

Transfusion

DOI

ISSN

0041-1132

Publication Date

October 1991

Volume

31

Issue

8

Start / End Page

756 / 758

Location

United States

Related Subject Headings

  • Temperature
  • Middle Aged
  • Male
  • MNSs Blood-Group System
  • Humans
  • Hemolysis
  • Complement Activation
  • Cardiovascular System & Hematology
  • Autoantibodies
  • Antibody Specificity