Spatial inhomogeneities in the acoustic velocity of tissues degrade the contrast and resolution of diagnostic ultrasonic images. A system which iteratively adjusts the phases of signals transmitted and received from individual elements in a phased array scanner in order to restore image quality when imaging through inhomogeneous layers is described. The adjustments are selected to maximize a quality factor in an operator-selectable region-of-interest. The use of several quality factors in improving image quality, including the average local and the peak echo magnitude of diffuse and point-like targets and integral powers of these magnitudes were investigated. Theory and experimental results related to these investigations is presented.

Duke Scholars

Published In

Proceedings of SPIE the International Society for Optical Engineering

DOI

EISSN

1996-756X

ISSN

0277-786X

Publication Date

July 1, 1990

Volume

1231

Start / End Page

40 / 49

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Trahey, G. E., & Zhao, D. (1990). Quality factors for phase aberration correction in medical ultrasound. Proceedings of SPIE the International Society for Optical Engineering, 1231, 40–49. https://doi.org/10.1117/12.18782
Trahey, G. E., and D. Zhao. “Quality factors for phase aberration correction in medical ultrasound.” Proceedings of SPIE the International Society for Optical Engineering 1231 (July 1, 1990): 40–49. https://doi.org/10.1117/12.18782.
Trahey GE, Zhao D. Quality factors for phase aberration correction in medical ultrasound. Proceedings of SPIE the International Society for Optical Engineering. 1990 Jul 1;1231:40–9.
Trahey, G. E., and D. Zhao. “Quality factors for phase aberration correction in medical ultrasound.” Proceedings of SPIE the International Society for Optical Engineering, vol. 1231, July 1990, pp. 40–49. Scopus, doi:10.1117/12.18782.
Trahey GE, Zhao D. Quality factors for phase aberration correction in medical ultrasound. Proceedings of SPIE the International Society for Optical Engineering. 1990 Jul 1;1231:40–49.

Published In

Proceedings of SPIE the International Society for Optical Engineering

DOI

EISSN

1996-756X

ISSN

0277-786X

Publication Date

July 1, 1990

Volume

1231

Start / End Page

40 / 49

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering