Work in progress: hybrid temporal-energy subtraction in digital fluoroscopy.
Publication
, Journal Article
Van Lysel, MS; Dobbins, JT; Peppler, WW; Hasegawa, BH; Lee, CS; Mistretta, CA; Zarnstorff, WC; Crummy, AB; Kubal, W; Bergsjordet, B ...
Published in: Radiology
June 1983
Initial clinical results using a digital fluoroscopic implementation of the combined time-energy ("hybrid") subtraction technique are described, with emphasis on carotid and renal imaging. Where patient motion artifacts are due to soft-tissue motion alone, hybrid subtraction can remove them. Due to the need for a finite separation time between high- and low-energy pairs, however, the present implementation of the hybrid technique is not completely immune to soft-tissue motion. The intrinsic signal-to-noise ratio of hybrid imaging is less than that of conventional temporal subtraction. However, since the low-energy temporal subtraction images are included in the hybrid data set, the diagnostic quality of the examination is not compromised.
Duke Scholars
Published In
Radiology
DOI
ISSN
0033-8419
Publication Date
June 1983
Volume
147
Issue
3
Start / End Page
869 / 874
Location
United States
Related Subject Headings
- Subtraction Technique
- Nuclear Medicine & Medical Imaging
- Humans
- Fluoroscopy
- Computers
- Carotid Arteries
- Angiography
- Analog-Digital Conversion
- 3202 Clinical sciences
- 11 Medical and Health Sciences
Citation
APA
Chicago
ICMJE
MLA
NLM
Van Lysel, M. S., Dobbins, J. T., Peppler, W. W., Hasegawa, B. H., Lee, C. S., Mistretta, C. A., … Sackett, J. F. (1983). Work in progress: hybrid temporal-energy subtraction in digital fluoroscopy. Radiology, 147(3), 869–874. https://doi.org/10.1148/radiology.147.3.6342038
Van Lysel, M. S., J. T. Dobbins, W. W. Peppler, B. H. Hasegawa, C. S. Lee, C. A. Mistretta, W. C. Zarnstorff, et al. “Work in progress: hybrid temporal-energy subtraction in digital fluoroscopy.” Radiology 147, no. 3 (June 1983): 869–74. https://doi.org/10.1148/radiology.147.3.6342038.
Van Lysel MS, Dobbins JT, Peppler WW, Hasegawa BH, Lee CS, Mistretta CA, et al. Work in progress: hybrid temporal-energy subtraction in digital fluoroscopy. Radiology. 1983 Jun;147(3):869–74.
Van Lysel, M. S., et al. “Work in progress: hybrid temporal-energy subtraction in digital fluoroscopy.” Radiology, vol. 147, no. 3, June 1983, pp. 869–74. Pubmed, doi:10.1148/radiology.147.3.6342038.
Van Lysel MS, Dobbins JT, Peppler WW, Hasegawa BH, Lee CS, Mistretta CA, Zarnstorff WC, Crummy AB, Kubal W, Bergsjordet B, Strother CM, Sackett JF. Work in progress: hybrid temporal-energy subtraction in digital fluoroscopy. Radiology. 1983 Jun;147(3):869–874.
Published In
Radiology
DOI
ISSN
0033-8419
Publication Date
June 1983
Volume
147
Issue
3
Start / End Page
869 / 874
Location
United States
Related Subject Headings
- Subtraction Technique
- Nuclear Medicine & Medical Imaging
- Humans
- Fluoroscopy
- Computers
- Carotid Arteries
- Angiography
- Analog-Digital Conversion
- 3202 Clinical sciences
- 11 Medical and Health Sciences