Geometrical properties of a digital beam attenuator system.

Publication ,  Journal Article
Hasegawa, BH; Dobbins, JT; Naimuddin, S; Peppler, WW; Mistretta, CA
Published in: Med Phys
1987

A digital beam attenuator system has been developed to automatically generate patient-specific compensating filters for chest radiography. An initial low-dose test image is used to generate the attenuator, which is fabricated by overprinting multiple layers of a heavy-metal material onto a nonattenuating substrate. The attenuator is subsequently inserted into the x-ray beam for a final compensated radiograph. The effects of focal spot blurring and limited attenuator resolution result in the final compensated image containing only high-spatial frequency information. The frequency response of the process is not strictly describable by a modulation transfer function, but an approximation of the frequencies remaining in the compensated image is obtained for low-contrast conditions. It is found that a 4 X 4 blurring function on the original 64 X 64 test image is required for the attenuator to give appropriate compensated image appearance. A proposed attenuator printing scheme prints the attenuator in a 16 X 16 matrix, staggering successively printed layers to achieve the required 64 X 64 sampling with appropriate blurring. The resulting compensated image has good anatomical definition and contains a frequency response similar to that obtained by compensation techniques being investigated by Plewes and Sorenson.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

1987

Volume

14

Issue

3

Start / End Page

314 / 321

Location

United States

Related Subject Headings

  • Radiography, Thoracic
  • Nuclear Medicine & Medical Imaging
  • Models, Anatomic
  • Humans
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Hasegawa, B. H., Dobbins, J. T., Naimuddin, S., Peppler, W. W., & Mistretta, C. A. (1987). Geometrical properties of a digital beam attenuator system. Med Phys, 14(3), 314–321. https://doi.org/10.1118/1.596086
Hasegawa, B. H., J. T. Dobbins, S. Naimuddin, W. W. Peppler, and C. A. Mistretta. “Geometrical properties of a digital beam attenuator system.Med Phys 14, no. 3 (1987): 314–21. https://doi.org/10.1118/1.596086.
Hasegawa BH, Dobbins JT, Naimuddin S, Peppler WW, Mistretta CA. Geometrical properties of a digital beam attenuator system. Med Phys. 1987;14(3):314–21.
Hasegawa, B. H., et al. “Geometrical properties of a digital beam attenuator system.Med Phys, vol. 14, no. 3, 1987, pp. 314–21. Pubmed, doi:10.1118/1.596086.
Hasegawa BH, Dobbins JT, Naimuddin S, Peppler WW, Mistretta CA. Geometrical properties of a digital beam attenuator system. Med Phys. 1987;14(3):314–321.

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

1987

Volume

14

Issue

3

Start / End Page

314 / 321

Location

United States

Related Subject Headings

  • Radiography, Thoracic
  • Nuclear Medicine & Medical Imaging
  • Models, Anatomic
  • Humans
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences