MR microscopy of the rat lung using projection reconstruction.
Publication
, Journal Article
Gewalt, SL; Glover, GH; Hedlund, LW; Cofer, GP; MacFall, JR; Johnson, GA
Published in: Magn Reson Med
January 1993
Projection reconstruction has been implemented with self-refocused selection pulses on a small bore, 2.0 T MR microscope, to allow imaging of lung parenchyma. Scan synchronous ventilation and cardiac gating have been integrated with the sequence to minimize motion artifacts. A systematic survey of the pulse sequence parameters has been undertaken in conjunction with the biological gating parameters to optimize resolution and signal-to-noise (SNR). The resulting projection images with effective echo time of < 300 microseconds allow definition of lung parenchyma with an SNR improvement of approximately 15 x over a more conventional 2DFT short echo gradient sequence.
Duke Scholars
Altmetric Attention Stats
Dimensions Citation Stats
Published In
Magn Reson Med
DOI
ISSN
0740-3194
Publication Date
January 1993
Volume
29
Issue
1
Start / End Page
99 / 106
Location
United States
Related Subject Headings
- Rats, Sprague-Dawley
- Rats
- Nuclear Medicine & Medical Imaging
- Microscopy
- Magnetic Resonance Imaging
- Lung
- Female
- Animals
- 4003 Biomedical engineering
- 0903 Biomedical Engineering
Citation
APA
Chicago
ICMJE
MLA
NLM
Gewalt, S. L., Glover, G. H., Hedlund, L. W., Cofer, G. P., MacFall, J. R., & Johnson, G. A. (1993). MR microscopy of the rat lung using projection reconstruction. Magn Reson Med, 29(1), 99–106. https://doi.org/10.1002/mrm.1910290117
Gewalt, S. L., G. H. Glover, L. W. Hedlund, G. P. Cofer, J. R. MacFall, and G. A. Johnson. “MR microscopy of the rat lung using projection reconstruction.” Magn Reson Med 29, no. 1 (January 1993): 99–106. https://doi.org/10.1002/mrm.1910290117.
Gewalt SL, Glover GH, Hedlund LW, Cofer GP, MacFall JR, Johnson GA. MR microscopy of the rat lung using projection reconstruction. Magn Reson Med. 1993 Jan;29(1):99–106.
Gewalt, S. L., et al. “MR microscopy of the rat lung using projection reconstruction.” Magn Reson Med, vol. 29, no. 1, Jan. 1993, pp. 99–106. Pubmed, doi:10.1002/mrm.1910290117.
Gewalt SL, Glover GH, Hedlund LW, Cofer GP, MacFall JR, Johnson GA. MR microscopy of the rat lung using projection reconstruction. Magn Reson Med. 1993 Jan;29(1):99–106.
Published In
Magn Reson Med
DOI
ISSN
0740-3194
Publication Date
January 1993
Volume
29
Issue
1
Start / End Page
99 / 106
Location
United States
Related Subject Headings
- Rats, Sprague-Dawley
- Rats
- Nuclear Medicine & Medical Imaging
- Microscopy
- Magnetic Resonance Imaging
- Lung
- Female
- Animals
- 4003 Biomedical engineering
- 0903 Biomedical Engineering