Skip to main content

Development and characterization of a vitreous mimicking material for radiation force imaging.

Publication ,  Journal Article
Negron, LA; Viola, F; Black, EP; Toth, CA; Walker, WF
Published in: IEEE Trans Ultrason Ferroelectr Freq Control
November 2002

In many medical ultrasound applications tissue-mimicking phantoms are of fundamental importance for the performance of controlled experiments. Traditionally, such phantoms have been constructed using gelatin and agar gels. Although the use of these materials has become standard, few alternative materials have not been fully explored. In this paper, we present a protocol developed in our laboratory that reliably produces very soft, acrylamide-based phantoms that can mimic both acoustical and mechanical characteristics of the vitreous body of the eye. Following the described protocol, a series of phantoms were constructed ranging in acrylamide concentration from 1.60% to 1.70%. Measurements across the series yielded attenuation coefficients of 0.067-0.140 dB/cm/MHz, depending on acrylamide concentration. Speed of sound ranged between 1499 and 1510 m/s, also depending on acrylamide concentration. Published values for the vitreous gel indicate an attenuation of 0.10 dB/cm/MHz and a speed of sound of 1510 m/s, making our phantoms an excellent analog of this tissue. One application of these acrylamide phantoms is to test the efficacy of the Kinetic Acoustic Vitreoretinal Examination (KAVE), a tool developed in our laboratory with the potential to aid in the diagnosis of vitreoretinal disorders. KAVE utilizes acoustic radiation force to generate small, localized displacements within the vitreous-mimicking gel. These localized displacements are quantified to yield maximum displacement, relative elasticity, and relative viscosity images. We present KAVE images of a set of four phantoms with different gel concentrations. Although B-mode and relative viscosity images exhibit no significant differences, maximum displacement, and relative elasticity images clearly differentiate gels of different concentrations. Maximum displacements ranged between 30 and 5 microns, depending on acrylamide concentration. The results presented in this paper show that soft gel phantoms can be produced in a range of elasticities not previously reported, and that these phantoms are useful for testing ultrasound instruments designed for evaluation of the vitreous gel. Furthermore, the use of acrylamide-based gels may also offer a valuable and attractive alternative for many other ultrasound applications.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

IEEE Trans Ultrason Ferroelectr Freq Control

DOI

ISSN

0885-3010

Publication Date

November 2002

Volume

49

Issue

11

Start / End Page

1543 / 1551

Location

United States

Related Subject Headings

  • Vitreous Body
  • Viscosity
  • Ultrasonography
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Quality Control
  • Phantoms, Imaging
  • Materials Testing
  • Equipment Failure Analysis
  • Equipment Design
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Negron, L. A., Viola, F., Black, E. P., Toth, C. A., & Walker, W. F. (2002). Development and characterization of a vitreous mimicking material for radiation force imaging. IEEE Trans Ultrason Ferroelectr Freq Control, 49(11), 1543–1551. https://doi.org/10.1109/tuffc.2002.1049736
Negron, Laura A., Francesco Viola, Eric P. Black, Cynthia A. Toth, and William F. Walker. “Development and characterization of a vitreous mimicking material for radiation force imaging.IEEE Trans Ultrason Ferroelectr Freq Control 49, no. 11 (November 2002): 1543–51. https://doi.org/10.1109/tuffc.2002.1049736.
Negron LA, Viola F, Black EP, Toth CA, Walker WF. Development and characterization of a vitreous mimicking material for radiation force imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2002 Nov;49(11):1543–51.
Negron, Laura A., et al. “Development and characterization of a vitreous mimicking material for radiation force imaging.IEEE Trans Ultrason Ferroelectr Freq Control, vol. 49, no. 11, Nov. 2002, pp. 1543–51. Pubmed, doi:10.1109/tuffc.2002.1049736.
Negron LA, Viola F, Black EP, Toth CA, Walker WF. Development and characterization of a vitreous mimicking material for radiation force imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2002 Nov;49(11):1543–1551.

Published In

IEEE Trans Ultrason Ferroelectr Freq Control

DOI

ISSN

0885-3010

Publication Date

November 2002

Volume

49

Issue

11

Start / End Page

1543 / 1551

Location

United States

Related Subject Headings

  • Vitreous Body
  • Viscosity
  • Ultrasonography
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Quality Control
  • Phantoms, Imaging
  • Materials Testing
  • Equipment Failure Analysis
  • Equipment Design