An experimental comparison of detector performance for direct and indirect digital radiography systems.

Publication ,  Journal Article
Samei, E; Flynn, MJ
Published in: Med Phys
April 2003

Current flat-panel detectors either directly convert x-ray energy to electronic charge or use indirect conversion with an intermediate optical process. The purpose of this work was to compare direct and indirect detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Measurements were made on three flat-panel detectors, Hologic Direct-Ray DR-1000 (DRC), GE Revolution XQ/i (XQ/i), and Philips Digital Diagnost (DiDi) using the IEC-defined RQA5 (approximately 74 kVp, 21 mm Al) and RQA9 (approximately 120 kVp, 40 mm Al) radiographic techniques. The presampled MTFs of the systems were measured using an edge method [Samei et al., Med. Phys. 25, 102 (1998)]. The NPS of the systems were determined for a range of exposure levels by two-dimensional (2D) Fourier analysis of uniformly exposed radiographs [Flynn and Samei, Med. Phys. 26, 1612 (1999)]. The DQEs were assessed from the measured MTF, NPS, exposure, and estimated ideal signal-to-noise ratios. For the direct system, the MTF was found to be significantly higher than that for the indirect systems and very close to an ideal function associated with the detector pixel size. The NPS for the direct system was found to be constant in relation to frequency. For the XQ/i and DRC systems, the DQE results reflected expected differences based on the absorption efficiency of the different detector materials. Using RQA5, the measured DQE values in the diagonal (and axial) direction(s) at spatial frequencies of 0.15 mm(-1) and 2.5 mm(-1) were 64% (64%) and 20% (15%) for the XQ/i system, and 38% (38%) and 20% (20%) for the DRC, respectively. The DQE results of the DiDi system were difficult to interpret due to additional preprocessing steps in that system.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

April 2003

Volume

30

Issue

4

Start / End Page

608 / 622

Location

United States

Related Subject Headings

  • X-Ray Intensifying Screens
  • Transducers
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radiographic Image Enhancement
  • Nuclear Medicine & Medical Imaging
  • Equipment Failure Analysis
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Samei, E., & Flynn, M. J. (2003). An experimental comparison of detector performance for direct and indirect digital radiography systems. Med Phys, 30(4), 608–622. https://doi.org/10.1118/1.1561285
Samei, Ehsan, and Michael J. Flynn. “An experimental comparison of detector performance for direct and indirect digital radiography systems.Med Phys 30, no. 4 (April 2003): 608–22. https://doi.org/10.1118/1.1561285.
Samei, Ehsan, and Michael J. Flynn. “An experimental comparison of detector performance for direct and indirect digital radiography systems.Med Phys, vol. 30, no. 4, Apr. 2003, pp. 608–22. Pubmed, doi:10.1118/1.1561285.

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

April 2003

Volume

30

Issue

4

Start / End Page

608 / 622

Location

United States

Related Subject Headings

  • X-Ray Intensifying Screens
  • Transducers
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radiographic Image Enhancement
  • Nuclear Medicine & Medical Imaging
  • Equipment Failure Analysis
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis