Pediatric chest MDCT using tube current modulation: effect on radiation dose with breast shielding.

Publication ,  Journal Article
Coursey, C; Frush, DP; Yoshizumi, T; Toncheva, G; Nguyen, G; Greenberg, SB
Published in: AJR Am J Roentgenol
January 2008

OBJECTIVE: The purpose of our study was to assess the effect on radiation dose and image noise during pediatric chest 16-MDCT using automatic tube current modulation and bismuth breast shields. MATERIALS AND METHODS: Age-based chest 16-MDCT was performed on an anthropomorphic phantom representing a 5-year-old child. Two scans were obtained in each of four sequences: first, without a shield; second, with a 2-ply bismuth shield; third, using automatic tube current modulation with a scout image obtained after placement of the shield; and fourth, using automatic tube current modulation with a scout image obtained before placement of the shield. Metal oxide semiconductor field effect transistor technology was used to measure the radiation dose in 20 organ locations. Effective dose was estimated using the console dose-length product. Noise was measured by recording the SD of Hounsfield units in identical regions of interest. RESULTS: The bismuth breast shield reduced the dose to the breast by 26%. Shielding and automatic tube current modulation reduced the breast dose by 52%. Multiple organ doses were lowest when the shield was placed after the scout radiograph had been obtained. When the shield was placed after the scout image was obtained, the mean noise in the range of shielding increased from 11.4 to 13.1 H (superior mediastinum) and from 10.0 to 12.8 H (heart) (p < 0.01). Increased noise, however, was near the target noise index (measured in SD of Hounsfield units) of 12.0 H (SD). Using automatic tube current modulation, the effective dose was reduced by 35% when the shield was placed after the scout and by 20% when the shield was present in the scout. CONCLUSION: The greatest dose reduction is achieved by placing the shield after obtaining the scout image to avoid Auto mA compensation due to density of shield. With this technique, image noise increased but remained close to the target noise index.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

AJR Am J Roentgenol

DOI

EISSN

1546-3141

Publication Date

January 2008

Volume

190

Issue

1

Start / End Page

W54 / W61

Location

United States

Related Subject Headings

  • Tomography, X-Ray Computed
  • Skin
  • Radiography, Thoracic
  • Radiographic Image Enhancement
  • Radiation Protection
  • Radiation Dosage
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Manikins
  • Lung
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Coursey, C., Frush, D. P., Yoshizumi, T., Toncheva, G., Nguyen, G., & Greenberg, S. B. (2008). Pediatric chest MDCT using tube current modulation: effect on radiation dose with breast shielding. AJR Am J Roentgenol, 190(1), W54–W61. https://doi.org/10.2214/AJR.07.2017
Coursey, Courtney, Donald P. Frush, Terry Yoshizumi, Greta Toncheva, Giao Nguyen, and S Bruce Greenberg. “Pediatric chest MDCT using tube current modulation: effect on radiation dose with breast shielding.AJR Am J Roentgenol 190, no. 1 (January 2008): W54–61. https://doi.org/10.2214/AJR.07.2017.
Coursey C, Frush DP, Yoshizumi T, Toncheva G, Nguyen G, Greenberg SB. Pediatric chest MDCT using tube current modulation: effect on radiation dose with breast shielding. AJR Am J Roentgenol. 2008 Jan;190(1):W54–61.
Coursey, Courtney, et al. “Pediatric chest MDCT using tube current modulation: effect on radiation dose with breast shielding.AJR Am J Roentgenol, vol. 190, no. 1, Jan. 2008, pp. W54–61. Pubmed, doi:10.2214/AJR.07.2017.
Coursey C, Frush DP, Yoshizumi T, Toncheva G, Nguyen G, Greenberg SB. Pediatric chest MDCT using tube current modulation: effect on radiation dose with breast shielding. AJR Am J Roentgenol. 2008 Jan;190(1):W54–W61.

Published In

AJR Am J Roentgenol

DOI

EISSN

1546-3141

Publication Date

January 2008

Volume

190

Issue

1

Start / End Page

W54 / W61

Location

United States

Related Subject Headings

  • Tomography, X-Ray Computed
  • Skin
  • Radiography, Thoracic
  • Radiographic Image Enhancement
  • Radiation Protection
  • Radiation Dosage
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Manikins
  • Lung