Skip to main content

New ways to measure intraocular pressure.

Publication ,  Journal Article
ElMallah, MK; Asrani, SG
Published in: Curr Opin Ophthalmol
March 2008

PURPOSE OF REVIEW: In the last 10 years, several new means to measure intraocular pressure have emerged. This review covers recent findings concerning four new technologies: the ocular response analyzer, dynamic contour tonometry, rebound tonometry and the Proview phosphene tonometer. RECENT FINDINGS: The ocular response analyzer provides measurements of corneal biomechanics, including corneal hysteresis. Intraocular pressure readings from the ocular response analyzer have correlated well with Goldmann applanation tonometry and seem to be independent of corneal thickness in nonglaucoma patients; however, further studies are needed to determine whether this is true in glaucoma patients. Dynamic contour tonometry also appears to give pressure readings that are independent of corneal thickness. Rebound tonometry is convenient, can be used without topical anesthesia and appears to correlate well with Goldmann tonometry; however, pressure readings from rebound tonometry are not independent of corneal properties. Use of the Proview phosphene tonometer appears to decrease patient anxiety regarding their glaucoma; however, studies have not been supportive of its accuracy. SUMMARY: Dynamic contour tonometry provides intraocular pressure readings that are less dependent on corneal properties than Goldmann applanation tonometry. Rebound tonometry appears to correlate well with Goldmann tonometry and can be used without topical anesthesia.

Duke Scholars

Published In

Curr Opin Ophthalmol

DOI

ISSN

1040-8738

Publication Date

March 2008

Volume

19

Issue

2

Start / End Page

122 / 126

Location

United States

Related Subject Headings

  • Tonometry, Ocular
  • Ophthalmology & Optometry
  • Intraocular Pressure
  • Humans
  • Cornea
  • Biomechanical Phenomena
  • 3212 Ophthalmology and optometry
  • 1113 Opthalmology and Optometry
 

Citation

APA
Chicago
ICMJE
MLA
NLM
ElMallah, M. K., & Asrani, S. G. (2008). New ways to measure intraocular pressure. Curr Opin Ophthalmol, 19(2), 122–126. https://doi.org/10.1097/ICU.0b013e3282f391ae
ElMallah, Mohammed K., and Sanjay G. Asrani. “New ways to measure intraocular pressure.Curr Opin Ophthalmol 19, no. 2 (March 2008): 122–26. https://doi.org/10.1097/ICU.0b013e3282f391ae.
ElMallah MK, Asrani SG. New ways to measure intraocular pressure. Curr Opin Ophthalmol. 2008 Mar;19(2):122–6.
ElMallah, Mohammed K., and Sanjay G. Asrani. “New ways to measure intraocular pressure.Curr Opin Ophthalmol, vol. 19, no. 2, Mar. 2008, pp. 122–26. Pubmed, doi:10.1097/ICU.0b013e3282f391ae.
ElMallah MK, Asrani SG. New ways to measure intraocular pressure. Curr Opin Ophthalmol. 2008 Mar;19(2):122–126.

Published In

Curr Opin Ophthalmol

DOI

ISSN

1040-8738

Publication Date

March 2008

Volume

19

Issue

2

Start / End Page

122 / 126

Location

United States

Related Subject Headings

  • Tonometry, Ocular
  • Ophthalmology & Optometry
  • Intraocular Pressure
  • Humans
  • Cornea
  • Biomechanical Phenomena
  • 3212 Ophthalmology and optometry
  • 1113 Opthalmology and Optometry