The detective quantum efficiency (DQE) of an x-ray digital imaging detector was determined independently by the three participants of this study, using the same data set consisting of edge and flat field images. The aim was to assess the possible variation in DQE originating from established, but slightly different, data processing methods used by different groups. For the case evaluated in this study differences in DQE of up to +/-15% compared to the mean were found. The differences could be traced back mainly to differences in the modulation transfer function (MTF) and noise power spectrum (NPS) determination. Of special importance is the inclusion of a possible low-frequency drop in MTF and the proper handling of signal offsets for the determination of the NPS. When accounting for these factors the deviation between the evaluations reduced to approximately +/-5%. It is expected that the recently published standard on DQE determination will further reduce variations in the data evaluation and thus in the results of DQE measurements.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

August 2004

Volume

31

Issue

8

Start / End Page

2205 / 2211

Location

United States

Related Subject Headings

  • X-Rays
  • Radiographic Image Interpretation, Computer-Assisted
  • Nuclear Medicine & Medical Imaging
  • Models, Theoretical
  • Computer Simulation
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Neitzel, U., Günther-Kohfahl, S., Borasi, G., & Samei, E. (2004). Determination of the detective quantum efficiency of a digital x-ray detector: comparison of three evaluations using a common image data set. Med Phys, 31(8), 2205–2211. https://doi.org/10.1118/1.1766421
Neitzel, Ulrich, Susanne Günther-Kohfahl, Giovanni Borasi, and Ehsan Samei. “Determination of the detective quantum efficiency of a digital x-ray detector: comparison of three evaluations using a common image data set.Med Phys 31, no. 8 (August 2004): 2205–11. https://doi.org/10.1118/1.1766421.
Neitzel, Ulrich, et al. “Determination of the detective quantum efficiency of a digital x-ray detector: comparison of three evaluations using a common image data set.Med Phys, vol. 31, no. 8, Aug. 2004, pp. 2205–11. Pubmed, doi:10.1118/1.1766421.

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

August 2004

Volume

31

Issue

8

Start / End Page

2205 / 2211

Location

United States

Related Subject Headings

  • X-Rays
  • Radiographic Image Interpretation, Computer-Assisted
  • Nuclear Medicine & Medical Imaging
  • Models, Theoretical
  • Computer Simulation
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences