Skip to main content

Percutaneous balloon pulmonic valvuloplasty following treated endocarditis in a patient with congenital pulmonary valve stenosis.

Publication ,  Journal Article
Coberly, LA; Harrison, JK; Bashore, TM
Published in: Cathet Cardiovasc Diagn
December 1990

A 36-year-old woman with congenital pulmonary valve stenosis developed the rare complication of endocarditis of the valve. After successful sterilization of the valve, the patient underwent percutaneous balloon pulmonic valvuloplasty at a later date. The procedure successfully reduced the peak pulmonary valve gradient from 94 to 45 mm Hg. Percutaneous balloon valvuloplasty is the procedure of choice for treatment of congenital pulmonary valvular stenosis, even in the unusual patient who has healed endocarditis of the pulmonary valve.

Duke Scholars

Published In

Cathet Cardiovasc Diagn

DOI

ISSN

0098-6569

Publication Date

December 1990

Volume

21

Issue

4

Start / End Page

245 / 247

Location

United States

Related Subject Headings

  • Streptococcus mutans
  • Streptococcal Infections
  • Pulmonary Valve Stenosis
  • Pulmonary Valve
  • Humans
  • Hemodynamics
  • Female
  • Endocarditis, Bacterial
  • Catheterization
  • Cardiovascular System & Hematology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Coberly, L. A., Harrison, J. K., & Bashore, T. M. (1990). Percutaneous balloon pulmonic valvuloplasty following treated endocarditis in a patient with congenital pulmonary valve stenosis. Cathet Cardiovasc Diagn, 21(4), 245–247. https://doi.org/10.1002/ccd.1810210407
Coberly, L. A., J. K. Harrison, and T. M. Bashore. “Percutaneous balloon pulmonic valvuloplasty following treated endocarditis in a patient with congenital pulmonary valve stenosis.Cathet Cardiovasc Diagn 21, no. 4 (December 1990): 245–47. https://doi.org/10.1002/ccd.1810210407.
Coberly LA, Harrison JK, Bashore TM. Percutaneous balloon pulmonic valvuloplasty following treated endocarditis in a patient with congenital pulmonary valve stenosis. Cathet Cardiovasc Diagn. 1990 Dec;21(4):245–7.
Coberly, L. A., et al. “Percutaneous balloon pulmonic valvuloplasty following treated endocarditis in a patient with congenital pulmonary valve stenosis.Cathet Cardiovasc Diagn, vol. 21, no. 4, Dec. 1990, pp. 245–47. Pubmed, doi:10.1002/ccd.1810210407.
Coberly LA, Harrison JK, Bashore TM. Percutaneous balloon pulmonic valvuloplasty following treated endocarditis in a patient with congenital pulmonary valve stenosis. Cathet Cardiovasc Diagn. 1990 Dec;21(4):245–247.

Published In

Cathet Cardiovasc Diagn

DOI

ISSN

0098-6569

Publication Date

December 1990

Volume

21

Issue

4

Start / End Page

245 / 247

Location

United States

Related Subject Headings

  • Streptococcus mutans
  • Streptococcal Infections
  • Pulmonary Valve Stenosis
  • Pulmonary Valve
  • Humans
  • Hemodynamics
  • Female
  • Endocarditis, Bacterial
  • Catheterization
  • Cardiovascular System & Hematology