Effect of balloon size and stepwise inflation technique on the acute results of Inoue mitral commissurotomy. Inoue Balloon Catheter Investigators.

Publication ,  Journal Article
Feldman, T; Carroll, JD; Herrmann, HC; Holmes, DR; Bashore, TM; Isner, JM; Dorros, G; Tobis, JM
Published in: Cathet Cardiovasc Diagn
March 1993

Currently percutaneous transvenous mitral commissurotomy (PTMC) is performed by most operators using stepwise inflation of the Inoue balloon beginning at a small diameter and increasing size by a sequence of inflations to nominal diameter. The effect of balloon size on procedure results using the Inoue balloon has not been evaluated. In 260 patients final balloon inflation was to nominal size in 42% of pts, larger than nominal size (overinflated) in 10%, and less than nominal size (underinflated) in 48% of pts. The average number of inflations was 3 (range 1-9). Pressure gradient and Doppler mitral regurgitation (MR) were assessed after each inflation. When MR increased, further inflations were not done. Patients in whom the balloon was overinflated underwent more balloon inflations than those in whom it was inflated to nominal size (5.0 +/- 2.1 vs. 2.9 +/- 1.4, p < 0.01). Those with balloon underinflation had fewer balloon inflations (2.4 +/- 1.2 vs. 2.9 +/- 1.4, p < 0.01). The post PTMC valve area in patients with overinflation was slightly less than those with nominal inflations (1.6 +/- 0.4 vs. 1.8 +/- 0.7), and with underinflation the valve area was no different compared to nominal inflation. Using a stepwise procedure, if mitral regurgitation was noted to increase after a balloon inflation, the procedure would be stopped even if less than an ideal result was achieved. Fewer inflations were done in patients in whom the balloon was inflated to less than nominal size because of the appearance of mitral regurgitation.(ABSTRACT TRUNCATED AT 250 WORDS)

Duke Scholars

Published In

Cathet Cardiovasc Diagn

DOI

ISSN

0098-6569

Publication Date

March 1993

Volume

28

Issue

3

Start / End Page

199 / 205

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Rheumatic Heart Disease
  • Mitral Valve Stenosis
  • Mitral Valve Insufficiency
  • Mitral Valve
  • Middle Aged
  • Male
  • Humans
  • Female
  • Equipment Design
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Feldman, T., Carroll, J. D., Herrmann, H. C., Holmes, D. R., Bashore, T. M., Isner, J. M., … Tobis, J. M. (1993). Effect of balloon size and stepwise inflation technique on the acute results of Inoue mitral commissurotomy. Inoue Balloon Catheter Investigators. Cathet Cardiovasc Diagn, 28(3), 199–205. https://doi.org/10.1002/ccd.1810280302
Feldman, T., J. D. Carroll, H. C. Herrmann, D. R. Holmes, T. M. Bashore, J. M. Isner, G. Dorros, and J. M. Tobis. “Effect of balloon size and stepwise inflation technique on the acute results of Inoue mitral commissurotomy. Inoue Balloon Catheter Investigators.Cathet Cardiovasc Diagn 28, no. 3 (March 1993): 199–205. https://doi.org/10.1002/ccd.1810280302.
Feldman T, Carroll JD, Herrmann HC, Holmes DR, Bashore TM, Isner JM, et al. Effect of balloon size and stepwise inflation technique on the acute results of Inoue mitral commissurotomy. Inoue Balloon Catheter Investigators. Cathet Cardiovasc Diagn. 1993 Mar;28(3):199–205.
Feldman, T., et al. “Effect of balloon size and stepwise inflation technique on the acute results of Inoue mitral commissurotomy. Inoue Balloon Catheter Investigators.Cathet Cardiovasc Diagn, vol. 28, no. 3, Mar. 1993, pp. 199–205. Pubmed, doi:10.1002/ccd.1810280302.
Feldman T, Carroll JD, Herrmann HC, Holmes DR, Bashore TM, Isner JM, Dorros G, Tobis JM. Effect of balloon size and stepwise inflation technique on the acute results of Inoue mitral commissurotomy. Inoue Balloon Catheter Investigators. Cathet Cardiovasc Diagn. 1993 Mar;28(3):199–205.

Published In

Cathet Cardiovasc Diagn

DOI

ISSN

0098-6569

Publication Date

March 1993

Volume

28

Issue

3

Start / End Page

199 / 205

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Rheumatic Heart Disease
  • Mitral Valve Stenosis
  • Mitral Valve Insufficiency
  • Mitral Valve
  • Middle Aged
  • Male
  • Humans
  • Female
  • Equipment Design