Skip to main content
Journal cover image

Hemodynamic effects of conventional and high frequency oscillatory ventilation in normal and septic piglets.

Publication ,  Journal Article
Osiovich, HC; Suguihara, C; Goldberg, RN; Hehre, D; Martinez, O; Bancalari, E
Published in: Biol Neonate
1991

The cardiovascular effects of high frequency oscillation (HFO) and conventional ventilation (CMV) were evaluated in 10 piglets prior to and during an infusion of group B streptococci (GBS). Animals were randomized to begin ventilation with either HFO or CMV. Arterial blood gases, cardiac output (CO), and pulmonary artery (Ppa), pulmonary wedge (Ppw) and arterial blood pressures were measured. These values were recorded at a mean airway pressure (MAP) of 2 cm H2O for both modes of ventilation after which a continuous infusion of GBS (4 X 10(7) CFU/kg/min) was begun. MAP was increased in both ventilators in the following sequence: 4, 8 and 12 cm H2O. Prior to GBS infusion, HFO was associated with small but significant changes in hemodynamic parameters when compared to CMV for the following: Ppa (15 +/- 4 vs. 13 +/- 4.0 mm Hg; p less than 0.03), Ppw (3 +/- 1 vs. 2 +/- 1 mm Hg; p less than 0.02), and CO (0.24 +/- 0.08 vs. 0.25 +/- 0.09 l/min/kg; p less than 0.05). Similar statistically significant increases in Ppa (p less than 0.005) and Ppw (p less than 0.0001), and decrease in CO (p less than 0.007) were present during GBS infusion when animals were ventilated with HFO, irrespective of the MAP used. Our results suggest that the use of HFO in both normal piglets and those receiving an infusion of GBS results in mild but consistent impairment in cardiovascular function compared to CMV. In summary, these data demonstrate that HFO has no beneficial effect compared to CMV at similar MAP in the management of the septic piglet model and may in fact further compromise the animal's hemodynamic status.

Duke Scholars

Published In

Biol Neonate

DOI

ISSN

0006-3126

Publication Date

1991

Volume

59

Issue

4

Start / End Page

244 / 252

Location

Switzerland

Related Subject Headings

  • Ventilators, Mechanical
  • Swine
  • Streptococcal Infections
  • Pediatrics
  • Hypoxia
  • High-Frequency Ventilation
  • Hemodynamics
  • Blood Pressure
  • Animals, Newborn
  • Animals
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Osiovich, H. C., Suguihara, C., Goldberg, R. N., Hehre, D., Martinez, O., & Bancalari, E. (1991). Hemodynamic effects of conventional and high frequency oscillatory ventilation in normal and septic piglets. Biol Neonate, 59(4), 244–252. https://doi.org/10.1159/000243350
Osiovich, H. C., C. Suguihara, R. N. Goldberg, D. Hehre, O. Martinez, and E. Bancalari. “Hemodynamic effects of conventional and high frequency oscillatory ventilation in normal and septic piglets.Biol Neonate 59, no. 4 (1991): 244–52. https://doi.org/10.1159/000243350.
Osiovich HC, Suguihara C, Goldberg RN, Hehre D, Martinez O, Bancalari E. Hemodynamic effects of conventional and high frequency oscillatory ventilation in normal and septic piglets. Biol Neonate. 1991;59(4):244–52.
Osiovich, H. C., et al. “Hemodynamic effects of conventional and high frequency oscillatory ventilation in normal and septic piglets.Biol Neonate, vol. 59, no. 4, 1991, pp. 244–52. Pubmed, doi:10.1159/000243350.
Osiovich HC, Suguihara C, Goldberg RN, Hehre D, Martinez O, Bancalari E. Hemodynamic effects of conventional and high frequency oscillatory ventilation in normal and septic piglets. Biol Neonate. 1991;59(4):244–252.
Journal cover image

Published In

Biol Neonate

DOI

ISSN

0006-3126

Publication Date

1991

Volume

59

Issue

4

Start / End Page

244 / 252

Location

Switzerland

Related Subject Headings

  • Ventilators, Mechanical
  • Swine
  • Streptococcal Infections
  • Pediatrics
  • Hypoxia
  • High-Frequency Ventilation
  • Hemodynamics
  • Blood Pressure
  • Animals, Newborn
  • Animals