Skip to main content

Disinfectant testing using a modified use-dilution method: collaborative study.

Publication ,  Journal Article
Cole, EC; Rutala, WA; Samsa, GP
Published in: J Assoc Off Anal Chem
1988

An initial collaborative study of the AOAC use-dilution method (UDM), used for bactericidal disinfectant efficacy testing, demonstrated extreme variability of test results among the 18 laboratories testing identical hospital disinfectants. In an effort to improve the method, 32 changes were made by the UDM Task Force. These changes represented improvements in quality assurance practices and elimination of method variability; however, the basic framework of the method was retained. A second collaborative trial was conducted to determine if the interlaboratory variability of test results could be reduced to an acceptable level using the modified UDM. Twelve of the original 18 laboratories participated in the second study. Each laboratory processed 60 penicylinders (P) for each of the 6 randomly selected, federally registered disinfectants and 3 test organisms (Staphylococcus aureus, Salmonella choleraesuis, Pseudomonas aeruginosa). The number of positive penicylinders (greater than 1 positive P/60 replicates = failure) for the 6 products when P. aeruginosa was used as the challenge organism ranged 1-30, 0-36, 0-15, 0-5, 0-3, and 0-60 for the 3 quaternaries and 3 phenolics, respectively. The results of the variance components analysis for P. aeruginosa and the other 2 organisms showed that the variance components for laboratories were not significantly reduced for any organism in this study. Such interlaboratory variability of results questions the use of the original or the modified UDM for registration purposes.

Duke Scholars

Published In

J Assoc Off Anal Chem

ISSN

0004-5756

Publication Date

1988

Volume

71

Issue

6

Start / End Page

1187 / 1194

Location

United States

Related Subject Headings

  • United States Environmental Protection Agency
  • United States
  • Staphylococcus aureus
  • Salmonella
  • Pseudomonas aeruginosa
  • Indicators and Reagents
  • Indicator Dilution Techniques
  • Disinfectants
  • Culture Media
  • Bacteriological Techniques
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Cole, E. C., Rutala, W. A., & Samsa, G. P. (1988). Disinfectant testing using a modified use-dilution method: collaborative study. J Assoc Off Anal Chem, 71(6), 1187–1194.
Cole, E. C., W. A. Rutala, and G. P. Samsa. “Disinfectant testing using a modified use-dilution method: collaborative study.J Assoc Off Anal Chem 71, no. 6 (1988): 1187–94.
Cole EC, Rutala WA, Samsa GP. Disinfectant testing using a modified use-dilution method: collaborative study. J Assoc Off Anal Chem. 1988;71(6):1187–94.
Cole, E. C., et al. “Disinfectant testing using a modified use-dilution method: collaborative study.J Assoc Off Anal Chem, vol. 71, no. 6, 1988, pp. 1187–94.
Cole EC, Rutala WA, Samsa GP. Disinfectant testing using a modified use-dilution method: collaborative study. J Assoc Off Anal Chem. 1988;71(6):1187–1194.

Published In

J Assoc Off Anal Chem

ISSN

0004-5756

Publication Date

1988

Volume

71

Issue

6

Start / End Page

1187 / 1194

Location

United States

Related Subject Headings

  • United States Environmental Protection Agency
  • United States
  • Staphylococcus aureus
  • Salmonella
  • Pseudomonas aeruginosa
  • Indicators and Reagents
  • Indicator Dilution Techniques
  • Disinfectants
  • Culture Media
  • Bacteriological Techniques