Water Cooled, In-cavity Apertures for High Power Operation of FEL Oscillators

Publication ,  Journal Article
Huang, S; Li, J; Wu, YK
Published in: Nucl. Instr. Methods A
2009

In an oscillator FEL, higher-order harmonic radiation from wigglers can cause serious damage to the downstream FEL resonator mirror and limit the maximum electron beam current for FEL operation due to thermal overload. These problems can be effectively dealt with for FELs driven by helical wigglers using a system to block off-axis wiggler harmonic radiation. In this paper, we report a new scheme to block the off-axis radiation from helical wigglers using a set of motorized, water-cooled, in-cavity apertures. These apertures can reduce the wiggler harmonic radiation power load on the downstream FEL resonator mirror by two orders of magnitude or more. With these apertures, we were able to operate the Duke FEL with record high intracavity power in infrared and visible wavelengths and extend FEL operation into ultraviolet wavelengths with a large electron beam current. The technique for limiting wiggler harmonic radiation using in-cavity apertures is expected to be useful for other types of FEL oscillators including high average power FEL oscillators driven by superconducting linacs.

Duke Scholars

Published In

Nucl. Instr. Methods A

Publication Date

2009

Volume

606

Start / End Page

762 / 769

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
  • 0201 Astronomical and Space Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Huang, S., Li, J., & Wu, Y. K. (2009). Water Cooled, In-cavity Apertures for High Power Operation of FEL Oscillators. Nucl. Instr. Methods A, 606, 762–769.
Huang, S., J. Li, and Y. K. Wu. “Water Cooled, In-cavity Apertures for High Power Operation of FEL Oscillators.” Nucl. Instr. Methods A 606 (2009): 762–69.
Huang S, Li J, Wu YK. Water Cooled, In-cavity Apertures for High Power Operation of FEL Oscillators. Nucl Instr Methods A. 2009;606:762–9.
Huang, S., et al. “Water Cooled, In-cavity Apertures for High Power Operation of FEL Oscillators.” Nucl. Instr. Methods A, vol. 606, 2009, pp. 762–69.
Huang S, Li J, Wu YK. Water Cooled, In-cavity Apertures for High Power Operation of FEL Oscillators. Nucl Instr Methods A. 2009;606:762–769.

Published In

Nucl. Instr. Methods A

Publication Date

2009

Volume

606

Start / End Page

762 / 769

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
  • 0201 Astronomical and Space Sciences