Skip to main content
Journal cover image

Pigtail catheters used for percutaneous fluid drainage: comparison of performance characteristics.

Journal articles  - Journal Article
Macha, DB; Thomas, J; Nelson, RC
Published in: Radiology
March 2006

PURPOSE: To compare the performance characteristics of various single-lumen all-purpose pigtail drainage catheters. MATERIALS AND METHODS: The following parameters were compared: flow rates between catheters of the same size, whether changing the fluid viscosity has any effect on catheter comparisons, the effect on flow of leaving an open three-way stopcock in the drainage pathway, the tendency of the catheters to kink, and catheter patency after kinking, as measured according to flow. All-purpose 8.0-, 8.3-, and 8.5-F (collectively referred to as 8-F); 10.0-, 10.2-, and 10.3-F (collectively referred to as 10-F); and 12.0-F pigtail drainage catheters from three manufacturers were evaluated. Data were compared by using two-tailed t tests after normal distributions were confirmed. P < .05 was considered to represent a significant difference. RESULTS: At comparison of the 8-F catheters, the C.R. Bard catheters demonstrated better flow rates than the Cook and Boston Scientific devices. Among the 10-F catheters, there were no significant differences in the flow rates of fluid with viscosity equivalent to that of water between the C.R. Bard and Boston Scientific catheters; however, both these catheter types demonstrated significantly (P < .05) better flow rates than the Cook devices. Among the 12-F catheters, the C.R. Bard catheters demonstrated significantly (P < .05) better flow rates than the other two catheter types. Changing the fluid viscosity caused no changes in comparison results. In all catheter groups, the presence of a stopcock significantly (P < .05) impaired flow. None of the evaluated catheters demonstrated a clear advantage in terms of patency or susceptibility to kinking. CONCLUSION: At comparison of the in vitro performances of catheters from different manufacturers, the C.R. Bard 8.0-F and Cook 10.2-F catheters had comparable flow rates, and flow rates through the C.R. Bard and Boston Scientific 10.0-F catheters were comparable to flow rates through the Cook and Boston Scientific 12.0-F catheters. Varying viscosity had no effect on comparisons of catheter flow rates; however, a stopcock between the vacuum source and the catheter was noted to impair flow rates in all brands and sizes of evaluated catheters.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Radiology

DOI

ISSN

0033-8419

Publication Date

March 2006

Volume

238

Issue

3

Start / End Page

1057 / 1063

Location

United States

Related Subject Headings

  • Rheology
  • Nuclear Medicine & Medical Imaging
  • In Vitro Techniques
  • Equipment Failure
  • Equipment Design
  • Drainage
  • Catheterization
  • 3202 Clinical sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Macha, D. B., Thomas, J., & Nelson, R. C. (2006). Pigtail catheters used for percutaneous fluid drainage: comparison of performance characteristics. Radiology, 238(3), 1057–1063. https://doi.org/10.1148/radiol.2383050578
Macha, Douglas B., John Thomas, and Rendon C. Nelson. “Pigtail catheters used for percutaneous fluid drainage: comparison of performance characteristics.Radiology 238, no. 3 (March 2006): 1057–63. https://doi.org/10.1148/radiol.2383050578.
Macha DB, Thomas J, Nelson RC. Pigtail catheters used for percutaneous fluid drainage: comparison of performance characteristics. Radiology. 2006 Mar;238(3):1057–63.
Macha, Douglas B., et al. “Pigtail catheters used for percutaneous fluid drainage: comparison of performance characteristics.Radiology, vol. 238, no. 3, Mar. 2006, pp. 1057–63. Pubmed, doi:10.1148/radiol.2383050578.
Macha DB, Thomas J, Nelson RC. Pigtail catheters used for percutaneous fluid drainage: comparison of performance characteristics. Radiology. 2006 Mar;238(3):1057–1063.
Journal cover image

Published In

Radiology

DOI

ISSN

0033-8419

Publication Date

March 2006

Volume

238

Issue

3

Start / End Page

1057 / 1063

Location

United States

Related Subject Headings

  • Rheology
  • Nuclear Medicine & Medical Imaging
  • In Vitro Techniques
  • Equipment Failure
  • Equipment Design
  • Drainage
  • Catheterization
  • 3202 Clinical sciences