Skip to main content
Journal cover image

Are hepatic and muscle T2 values different at 0.5 and 1.5 Tesla?

Publication ,  Journal Article
Bernardino, ME; Chaloupka, JC; Malko, JA; Chezmar, JL; Nelson, RC
Published in: Magn Reson Imaging
1989

In an effort to determine whether T2 values of liver and muscle change with increasing field strength, 144 abdominal MR examinations were retrospectively evaluated. These patients were evaluated with a dual echo T2-weighted spin-echo sequence. Eighty-two of the examinations were performed at 0.5 Tesla and 72 at 1.5 Tesla (T). Eleven of the patients were evaluated with both MR systems with the same sequences. T2 values were also obtained from a Fe NH4(SO4)2 12H2O phantom. The T2 values of liver decreased from 57.8 +/- 11.3 at 0.5 T to 43.7 +/- 8.3 at 1.5 T. The T2 values of muscle decreased from 44.2 +/- 9 at 0.5 T to 35.4 +/- 7.2 at 1.5 T. Patients who were examined on both systems also demonstrated a decrease in both liver and muscle T2 values. For concentrations in the range of hepatic T2's, the phantom demonstrated a decrease in T2 values from 0.5 to 1.5 T ranging from 20.3 to 23.4%. All the T2 changes were statistically significant (p less than .05). The findings suggest that T2 values may depend on field strength, or may vary due to other hardware-related differences.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Magn Reson Imaging

DOI

ISSN

0730-725X

Publication Date

1989

Volume

7

Issue

4

Start / End Page

363 / 367

Location

Netherlands

Related Subject Headings

  • Time Factors
  • Nuclear Medicine & Medical Imaging
  • Muscular Diseases
  • Muscles
  • Magnetic Resonance Imaging
  • Liver Diseases
  • Liver
  • Humans
  • Evaluation Studies as Topic
  • 3202 Clinical sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Bernardino, M. E., Chaloupka, J. C., Malko, J. A., Chezmar, J. L., & Nelson, R. C. (1989). Are hepatic and muscle T2 values different at 0.5 and 1.5 Tesla? Magn Reson Imaging, 7(4), 363–367. https://doi.org/10.1016/0730-725x(89)90485-2
Bernardino, M. E., J. C. Chaloupka, J. A. Malko, J. L. Chezmar, and R. C. Nelson. “Are hepatic and muscle T2 values different at 0.5 and 1.5 Tesla?Magn Reson Imaging 7, no. 4 (1989): 363–67. https://doi.org/10.1016/0730-725x(89)90485-2.
Bernardino ME, Chaloupka JC, Malko JA, Chezmar JL, Nelson RC. Are hepatic and muscle T2 values different at 0.5 and 1.5 Tesla? Magn Reson Imaging. 1989;7(4):363–7.
Bernardino, M. E., et al. “Are hepatic and muscle T2 values different at 0.5 and 1.5 Tesla?Magn Reson Imaging, vol. 7, no. 4, 1989, pp. 363–67. Pubmed, doi:10.1016/0730-725x(89)90485-2.
Bernardino ME, Chaloupka JC, Malko JA, Chezmar JL, Nelson RC. Are hepatic and muscle T2 values different at 0.5 and 1.5 Tesla? Magn Reson Imaging. 1989;7(4):363–367.
Journal cover image

Published In

Magn Reson Imaging

DOI

ISSN

0730-725X

Publication Date

1989

Volume

7

Issue

4

Start / End Page

363 / 367

Location

Netherlands

Related Subject Headings

  • Time Factors
  • Nuclear Medicine & Medical Imaging
  • Muscular Diseases
  • Muscles
  • Magnetic Resonance Imaging
  • Liver Diseases
  • Liver
  • Humans
  • Evaluation Studies as Topic
  • 3202 Clinical sciences