Reduction of artifacts in T2 -weighted PROPELLER in high-field preclinical imaging.

Publication ,  Journal Article
Pandit, P; Qi, Y; King, KF; Johnson, GA
Published in: Magn Reson Med
February 2011

A simple technique is implemented for correction of artifacts arising from nonuniform T(2) -weighting of k-space data in fast spin echo-based PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction). An additional blade with no phase-encoding gradients is acquired to generate the scaling factor used for the correction. Results from simulations and phantom experiments, as well as in vivo experiments in free-breathing mice, demonstrate the advantages of the proposed method. This technique is developed specifically for high-field imaging applications where T(2) decay is rapid.

Duke Scholars

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

February 2011

Volume

65

Issue

2

Start / End Page

538 / 543

Location

United States

Related Subject Headings

  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Neoplasm Transplantation
  • Mice
  • Magnetic Resonance Imaging
  • Lung Neoplasms
  • Image Enhancement
  • Artifacts
  • Animals
  • 4003 Biomedical engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Pandit, P., Qi, Y., King, K. F., & Johnson, G. A. (2011). Reduction of artifacts in T2 -weighted PROPELLER in high-field preclinical imaging. Magn Reson Med, 65(2), 538–543. https://doi.org/10.1002/mrm.22624
Pandit, Prachi, Yi Qi, Kevin F. King, and G Allan Johnson. “Reduction of artifacts in T2 -weighted PROPELLER in high-field preclinical imaging.Magn Reson Med 65, no. 2 (February 2011): 538–43. https://doi.org/10.1002/mrm.22624.
Pandit P, Qi Y, King KF, Johnson GA. Reduction of artifacts in T2 -weighted PROPELLER in high-field preclinical imaging. Magn Reson Med. 2011 Feb;65(2):538–43.
Pandit, Prachi, et al. “Reduction of artifacts in T2 -weighted PROPELLER in high-field preclinical imaging.Magn Reson Med, vol. 65, no. 2, Feb. 2011, pp. 538–43. Pubmed, doi:10.1002/mrm.22624.
Pandit P, Qi Y, King KF, Johnson GA. Reduction of artifacts in T2 -weighted PROPELLER in high-field preclinical imaging. Magn Reson Med. 2011 Feb;65(2):538–543.
Journal cover image

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

February 2011

Volume

65

Issue

2

Start / End Page

538 / 543

Location

United States

Related Subject Headings

  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Neoplasm Transplantation
  • Mice
  • Magnetic Resonance Imaging
  • Lung Neoplasms
  • Image Enhancement
  • Artifacts
  • Animals
  • 4003 Biomedical engineering