Skip to main content
Journal cover image

Ratio of germanium detector peak efficiencies at photon energies of 4.4 and 11.7 MeV: Experiment versus simulation

Publication ,  Journal Article
Carson, S; Iliadis, C; Cesaratto, J; Champagne, A; Downen, L; Ivanovic, M; Kelley, J; Longland, R; Newton, JR; Rusev, G; Tonchev, AP
Published in: Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
June 1, 2010

Full-energy peak efficiencies of germanium detectors are frequently investigated at γ-ray energies below 4 MeV using calibrated radioactive sources, while very accurate peak efficiencies for higher photon energies are essentially non-existent. Peak efficiencies in the energy range of E γ = 4212 MeV are crucial for a number of applications, including nuclear astrophysics measurements of fusion reactions and resonance fluorescence experiments. We report on a novel method, using the 163 keV resonance in the 11 B(p, γ)12C reaction, of measuring accurately the ratio of full-energy peak efficiencies at 4.44 and 11.66 MeV. We derive this ratio for three different detector-target distances (3, 12 and 26cm) directly from measured peak intensities and demonstrate that corrections are small (γ-ray branching ratios, angular correlations, coincidence summing). Our measured full-energy peak efficiency ratios have a precision of 1.4-1.6%. Another important goal of our study was to determine to what precision full-energy peak efficiencies at high γ-ray energies can be predicted using the simulation codes Geant3 and Geant4. We imaged our detector using computed tomography and radiographs in order to extract reliable detector crystal dimensions. Based on these results, extensive computer simulations are performed. We find that the simulation results agree with the measured peak efficiency ratios within an uncertainty of 1.6% for Geant4 and 2.6% for Geant3. Our results are useful for assigning uncertainties when peak efficiencies are extrapolated from low energy data to high energies based on simulations only. © 2010 Elsevier B.V.

Duke Scholars

Published In

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment

DOI

ISSN

0168-9002

Publication Date

June 1, 2010

Volume

618

Issue

1-3

Start / End Page

190 / 198

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
  • 0201 Astronomical and Space Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Carson, S., Iliadis, C., Cesaratto, J., Champagne, A., Downen, L., Ivanovic, M., … Tonchev, A. P. (2010). Ratio of germanium detector peak efficiencies at photon energies of 4.4 and 11.7 MeV: Experiment versus simulation. Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment, 618(1–3), 190–198. https://doi.org/10.1016/j.nima.2010.02.128
Carson, S., C. Iliadis, J. Cesaratto, A. Champagne, L. Downen, M. Ivanovic, J. Kelley, et al. “Ratio of germanium detector peak efficiencies at photon energies of 4.4 and 11.7 MeV: Experiment versus simulation.” Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 618, no. 1–3 (June 1, 2010): 190–98. https://doi.org/10.1016/j.nima.2010.02.128.
Carson S, Iliadis C, Cesaratto J, Champagne A, Downen L, Ivanovic M, et al. Ratio of germanium detector peak efficiencies at photon energies of 4.4 and 11.7 MeV: Experiment versus simulation. Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment. 2010 Jun 1;618(1–3):190–8.
Carson, S., et al. “Ratio of germanium detector peak efficiencies at photon energies of 4.4 and 11.7 MeV: Experiment versus simulation.” Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment, vol. 618, no. 1–3, June 2010, pp. 190–98. Scopus, doi:10.1016/j.nima.2010.02.128.
Carson S, Iliadis C, Cesaratto J, Champagne A, Downen L, Ivanovic M, Kelley J, Longland R, Newton JR, Rusev G, Tonchev AP. Ratio of germanium detector peak efficiencies at photon energies of 4.4 and 11.7 MeV: Experiment versus simulation. Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment. 2010 Jun 1;618(1–3):190–198.
Journal cover image

Published In

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment

DOI

ISSN

0168-9002

Publication Date

June 1, 2010

Volume

618

Issue

1-3

Start / End Page

190 / 198

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
  • 0201 Astronomical and Space Sciences