Skip to main content
Journal cover image

Climatology of ozone exceedences in the Atlanta metropolitan area: 1- hour vs 8-hour standard and the role of plume recirculation air pollution episodes

Publication ,  Journal Article
St. John, JC; Chameides, WL
Published in: Environmental Science and Technology
October 1, 1997

This work compares the relative frequencies of and meteorological conditions most conducive to exceedences of the current 1-h/120-ppbv national ambient air quality standard for ozone and the proposed revised standard based on daily maximum 8-h averages. Chemical and meteorological data gathered from 1987 through 1993 in Atlanta, GA, are used to determine the daily maximum 1-h and 8-h average ozone mixing ratios at each local monitoring site, during the ozone season for each year. The nature of the highest among the maxima and the concurrent local meteorological conditions are examined. We find a high degree of correlation between the daily maximum 1-h and 8-h averages (R2 = 0.92) in Atlanta, with an 8-h daily maximum concentration of 98 ppbv being climatologically equivalent to a 1-h daily maxima of 120 ppbv. Over the 7-year period investigated, exceedences of 8-h- averaged concentrations of 70, 80, and 90 ppbv were about 5, 3, and 2 times more frequent in Atlanta than exceedences of the current 1-h/120-ppbv standard. Meteorological conditions that fostered Atlanta's most severe 1-h and 8-h maximum ozone pollution events over the period were quite similar. The majority of the most extreme 1-h and 8-h events were associated with multiple-day episodes with very stagnant meteorological conditions and a recirculation and recooking of Atlanta's plume on consecutive days. These events, called 'plume recirculation' episodes, are distinct from other multiple-day episodes that were characterized by fairly steady winds, little or no recirculation, and more modest O3 concentrations. Plume recirculation episodes are among Atlanta's most severe O3 exceedences and therefore were chosen by the State of Georgia for urban airshed modeling in its most recent Stats Implementation Plan (SIP) and will likely remain the focus in future SiPs even if a new 8-h standard is promulgated.

Duke Scholars

Published In

Environmental Science and Technology

DOI

ISSN

0013-936X

Publication Date

October 1, 1997

Volume

31

Issue

10

Start / End Page

2797 / 2804

Related Subject Headings

  • Environmental Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
St. John, J. C., & Chameides, W. L. (1997). Climatology of ozone exceedences in the Atlanta metropolitan area: 1- hour vs 8-hour standard and the role of plume recirculation air pollution episodes. Environmental Science and Technology, 31(10), 2797–2804. https://doi.org/10.1021/es961068a
St. John, J. C., and W. L. Chameides. “Climatology of ozone exceedences in the Atlanta metropolitan area: 1- hour vs 8-hour standard and the role of plume recirculation air pollution episodes.” Environmental Science and Technology 31, no. 10 (October 1, 1997): 2797–2804. https://doi.org/10.1021/es961068a.
St. John, J. C., and W. L. Chameides. “Climatology of ozone exceedences in the Atlanta metropolitan area: 1- hour vs 8-hour standard and the role of plume recirculation air pollution episodes.” Environmental Science and Technology, vol. 31, no. 10, Oct. 1997, pp. 2797–804. Scopus, doi:10.1021/es961068a.
Journal cover image

Published In

Environmental Science and Technology

DOI

ISSN

0013-936X

Publication Date

October 1, 1997

Volume

31

Issue

10

Start / End Page

2797 / 2804

Related Subject Headings

  • Environmental Sciences