Multicenter automatic defibrillator implantation trial-cardiac resynchronization therapy (MADIT-CRT): design and clinical protocol.
Publication
, Journal Article
Moss, AJ; Brown, MW; Cannom, DS; Daubert, JP; Estes, M; Foster, E; Greenberg, HM; Hall, WJ; Higgins, SL; Klein, H; Pfeffer, M; Wilber, D; Zareba, W
Published in: Ann Noninvasive Electrocardiol
October 2005
The planned MADIT-CRT trial is designed to determine if CRT-D will reduce the risk of mortality and HF events by approximately 25% in subjects with ischemic (NYHA class I-II) and non-ischemic (NYHA class II) cardiomyopathy, left ventricular dysfunction (EF
Duke Scholars
Altmetric Attention Stats
Dimensions Citation Stats
Published In
Ann Noninvasive Electrocardiol
DOI
ISSN
1082-720X
Publication Date
October 2005
Volume
10
Issue
4 Suppl
Start / End Page
34 / 43
Location
United States
Related Subject Headings
- Ventricular Dysfunction, Left
- United States
- Treatment Outcome
- Risk Factors
- Risk Assessment
- Research Design
- Randomized Controlled Trials as Topic
- Prognosis
- Myocardial Ischemia
- Middle Aged
Citation
APA
Chicago
ICMJE
MLA
NLM
Moss, A. J., Brown, M. W., Cannom, D. S., Daubert, J. P., Estes, M., Foster, E., … Zareba, W. (2005). Multicenter automatic defibrillator implantation trial-cardiac resynchronization therapy (MADIT-CRT): design and clinical protocol. Ann Noninvasive Electrocardiol, 10(4 Suppl), 34–43. https://doi.org/10.1111/j.1542-474X.2005.00073.x
Moss, Arthur J., Mary W. Brown, David S. Cannom, James P. Daubert, Mark Estes, Elyse Foster, Henry M. Greenberg, et al. “Multicenter automatic defibrillator implantation trial-cardiac resynchronization therapy (MADIT-CRT): design and clinical protocol.” Ann Noninvasive Electrocardiol 10, no. 4 Suppl (October 2005): 34–43. https://doi.org/10.1111/j.1542-474X.2005.00073.x.
Moss AJ, Brown MW, Cannom DS, Daubert JP, Estes M, Foster E, et al. Multicenter automatic defibrillator implantation trial-cardiac resynchronization therapy (MADIT-CRT): design and clinical protocol. Ann Noninvasive Electrocardiol. 2005 Oct;10(4 Suppl):34–43.
Moss, Arthur J., et al. “Multicenter automatic defibrillator implantation trial-cardiac resynchronization therapy (MADIT-CRT): design and clinical protocol.” Ann Noninvasive Electrocardiol, vol. 10, no. 4 Suppl, Oct. 2005, pp. 34–43. Pubmed, doi:10.1111/j.1542-474X.2005.00073.x.
Moss AJ, Brown MW, Cannom DS, Daubert JP, Estes M, Foster E, Greenberg HM, Hall WJ, Higgins SL, Klein H, Pfeffer M, Wilber D, Zareba W. Multicenter automatic defibrillator implantation trial-cardiac resynchronization therapy (MADIT-CRT): design and clinical protocol. Ann Noninvasive Electrocardiol. 2005 Oct;10(4 Suppl):34–43.

Published In
Ann Noninvasive Electrocardiol
DOI
ISSN
1082-720X
Publication Date
October 2005
Volume
10
Issue
4 Suppl
Start / End Page
34 / 43
Location
United States
Related Subject Headings
- Ventricular Dysfunction, Left
- United States
- Treatment Outcome
- Risk Factors
- Risk Assessment
- Research Design
- Randomized Controlled Trials as Topic
- Prognosis
- Myocardial Ischemia
- Middle Aged