Operation of the OK-4/Duke storage ring FEL below 200 nm
Publication
, Journal Article
Litvinenko, VN; Park, SH; Pinayev, IV; Wu, Y
Published in: Nuclear Instruments and Methods in Physics Research Section A
December 2001
For a number of years the wavelength of 200 nm was a psychological barrier for FEL oscillators. The progress towards short wavelength was marginal since the OK-4/VEPP-3 storage ring FEL lased at 240 nm in 1988. After 10 years, in 1998, the OK-4/Duke FEL and the NIJI-IV FEL group moved the limit to 217 and 212 nm, respectively. Improvements of the OK-4/Duke storage ring FEL gain above 10% and the use of custom manufactured mirror coatings brought the success in August 1999. The OK-4 FEL lased in the range from 193.7 to 209.8 nm using electron energies from 500 to 800 MeV. In this paper, we present the description of the OK-4/Duke FEL up-grades and the lasing results below 200 nm obtained in August and October of 1999.
Duke Scholars
Published In
Nuclear Instruments and Methods in Physics Research Section A
Publication Date
December 2001
Volume
475
Start / End Page
195 / 204
Related Subject Headings
- Nuclear & Particles Physics
- 5106 Nuclear and plasma physics
- 0299 Other Physical Sciences
- 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
- 0201 Astronomical and Space Sciences
Citation
APA
Chicago
ICMJE
MLA
NLM
Litvinenko, V. N., Park, S. H., Pinayev, I. V., & Wu, Y. (2001). Operation of the OK-4/Duke storage ring FEL below 200 nm. Nuclear Instruments and Methods in Physics Research Section A, 475, 195–204.
Litvinenko, Vladimir N., Seong Hee Park, Igor V. Pinayev, and Ying Wu. “Operation of the OK-4/Duke storage ring FEL below 200 nm.” Nuclear Instruments and Methods in Physics Research Section A 475 (December 2001): 195–204.
Litvinenko VN, Park SH, Pinayev IV, Wu Y. Operation of the OK-4/Duke storage ring FEL below 200 nm. Nuclear Instruments and Methods in Physics Research Section A. 2001 Dec;475:195–204.
Litvinenko, Vladimir N., et al. “Operation of the OK-4/Duke storage ring FEL below 200 nm.” Nuclear Instruments and Methods in Physics Research Section A, vol. 475, Dec. 2001, pp. 195–204.
Litvinenko VN, Park SH, Pinayev IV, Wu Y. Operation of the OK-4/Duke storage ring FEL below 200 nm. Nuclear Instruments and Methods in Physics Research Section A. 2001 Dec;475:195–204.
Published In
Nuclear Instruments and Methods in Physics Research Section A
Publication Date
December 2001
Volume
475
Start / End Page
195 / 204
Related Subject Headings
- Nuclear & Particles Physics
- 5106 Nuclear and plasma physics
- 0299 Other Physical Sciences
- 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
- 0201 Astronomical and Space Sciences