Skip to main content
Journal cover image

Synthetic positron emission tomography-computed tomography images for use in perceptual studies.

Publication ,  Journal Article
D'Alessandro, B; Madsen, M; Samei, E; Li, X; Wooi-Tan, J; Berbaum, KS; Schartz, K; Caldwell, R; Zuckier, LS
Published in: Semin Nucl Med
November 2011

To better understand fundamental issues, perception studies of the fusion display would best be performed with a panel of lesions of variable location, size, intensity, and background. There are compelling reasons to use synthetic images that contain artificial lesions for perception research. A consideration of how to obtain this panel of lesions is the nucleus of the present review. This article is a conjoint effort of 3 groups that have joined together to review results from work that they and others have performed. The techniques we review include (1) substitution of lesions into a preexisting image matrix (either using actual prior patient-derived lesions or mathematically modeled artificial lesions), (2) addition of images (either in the attenuation-corrected image space or at an earlier stage before image reconstruction), and (3) simulation of the entire patient image. A judicious combination of the techniques discussed in this review may represent the most efficient pathway of simulating statistically varied but realistic appearing lesions.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Semin Nucl Med

DOI

EISSN

1558-4623

Publication Date

November 2011

Volume

41

Issue

6

Start / End Page

437 / 448

Location

United States

Related Subject Headings

  • Tomography, X-Ray Computed
  • Sensitivity and Specificity
  • Positron-Emission Tomography
  • Perception
  • Nuclear Medicine & Medical Imaging
  • Models, Biological
  • Image Processing, Computer-Assisted
  • Humans
  • Diagnostic Errors
  • Data Display
 

Citation

APA
Chicago
ICMJE
MLA
NLM
D’Alessandro, B., Madsen, M., Samei, E., Li, X., Wooi-Tan, J., Berbaum, K. S., … Zuckier, L. S. (2011). Synthetic positron emission tomography-computed tomography images for use in perceptual studies. Semin Nucl Med, 41(6), 437–448. https://doi.org/10.1053/j.semnuclmed.2011.06.007
D’Alessandro, Brian, Mark Madsen, Ehsan Samei, Xiang Li, Jin Wooi-Tan, Kevin S. Berbaum, Kevin Schartz, Robert Caldwell, and Lionel S. Zuckier. “Synthetic positron emission tomography-computed tomography images for use in perceptual studies.Semin Nucl Med 41, no. 6 (November 2011): 437–48. https://doi.org/10.1053/j.semnuclmed.2011.06.007.
D’Alessandro B, Madsen M, Samei E, Li X, Wooi-Tan J, Berbaum KS, et al. Synthetic positron emission tomography-computed tomography images for use in perceptual studies. Semin Nucl Med. 2011 Nov;41(6):437–48.
D’Alessandro, Brian, et al. “Synthetic positron emission tomography-computed tomography images for use in perceptual studies.Semin Nucl Med, vol. 41, no. 6, Nov. 2011, pp. 437–48. Pubmed, doi:10.1053/j.semnuclmed.2011.06.007.
D’Alessandro B, Madsen M, Samei E, Li X, Wooi-Tan J, Berbaum KS, Schartz K, Caldwell R, Zuckier LS. Synthetic positron emission tomography-computed tomography images for use in perceptual studies. Semin Nucl Med. 2011 Nov;41(6):437–448.
Journal cover image

Published In

Semin Nucl Med

DOI

EISSN

1558-4623

Publication Date

November 2011

Volume

41

Issue

6

Start / End Page

437 / 448

Location

United States

Related Subject Headings

  • Tomography, X-Ray Computed
  • Sensitivity and Specificity
  • Positron-Emission Tomography
  • Perception
  • Nuclear Medicine & Medical Imaging
  • Models, Biological
  • Image Processing, Computer-Assisted
  • Humans
  • Diagnostic Errors
  • Data Display