Skip to main content
Journal cover image

Enhanced effect of double-stacked intrastromal corneal ring segments in keratoconus.

Publication ,  Journal Article
Feldman, BH; Kim, T
Published in: J Cataract Refract Surg
February 2010

We present a patient with poor visual acuity and contact lens intolerance due to advanced keratoconus who had femtosecond-assisted placement of two 0.35 mm intrastromal corneal ring segments (ICRS) in the right eye. Postoperatively, both rings migrated inferiorly and overlapped each other in a double-stacked formation. This resulted in a dramatic central shift of the cone and flattening of the inferior paracentral cornea with significant improvement in vision. To our knowledge, this is the first report of double-stacked ICRS in a human cornea and raises the possibility that significantly thicker segments may provide enhanced anatomic and visual effects in some keratoectatic patients.

Duke Scholars

Published In

J Cataract Refract Surg

DOI

EISSN

1873-4502

Publication Date

February 2010

Volume

36

Issue

2

Start / End Page

332 / 335

Location

United States

Related Subject Headings

  • Visual Acuity
  • Prosthesis Implantation
  • Prostheses and Implants
  • Ophthalmology & Optometry
  • Middle Aged
  • Male
  • Keratoconus
  • Humans
  • Corneal Topography
  • Corneal Stroma
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Feldman, B. H., & Kim, T. (2010). Enhanced effect of double-stacked intrastromal corneal ring segments in keratoconus. J Cataract Refract Surg, 36(2), 332–335. https://doi.org/10.1016/j.jcrs.2009.07.026
Feldman, Brad H., and Terry Kim. “Enhanced effect of double-stacked intrastromal corneal ring segments in keratoconus.J Cataract Refract Surg 36, no. 2 (February 2010): 332–35. https://doi.org/10.1016/j.jcrs.2009.07.026.
Feldman BH, Kim T. Enhanced effect of double-stacked intrastromal corneal ring segments in keratoconus. J Cataract Refract Surg. 2010 Feb;36(2):332–5.
Feldman, Brad H., and Terry Kim. “Enhanced effect of double-stacked intrastromal corneal ring segments in keratoconus.J Cataract Refract Surg, vol. 36, no. 2, Feb. 2010, pp. 332–35. Pubmed, doi:10.1016/j.jcrs.2009.07.026.
Feldman BH, Kim T. Enhanced effect of double-stacked intrastromal corneal ring segments in keratoconus. J Cataract Refract Surg. 2010 Feb;36(2):332–335.
Journal cover image

Published In

J Cataract Refract Surg

DOI

EISSN

1873-4502

Publication Date

February 2010

Volume

36

Issue

2

Start / End Page

332 / 335

Location

United States

Related Subject Headings

  • Visual Acuity
  • Prosthesis Implantation
  • Prostheses and Implants
  • Ophthalmology & Optometry
  • Middle Aged
  • Male
  • Keratoconus
  • Humans
  • Corneal Topography
  • Corneal Stroma