Skip to main content
Journal cover image

Multiple breath-hold averaging (MBA) method for increased SNR in abdominal MRI.

Publication ,  Journal Article
Feinberg, DA; Rofsky, NM; Johnson, G
Published in: Magn Reson Med
December 1995

Breath-holding during MR imaging eliminates respiratory motion artifacts but places a major time constraint on data acquisition. This constraint limits image signal-to-noise ratio and hence spatial resolution. A new method, multiple breath-hold averaging, is presented that overcomes these time limitations. Several images are acquired in sequential breath-hold periods, separated by periods of normal breathing, and averaged. This averaged image shows the expected increase in SNR with surprisingly little blurring due to misregistration. SNR improvements can be traded for increased spatial resolution. The MBA methodology can also be applied to 3D data acquisitions, dynamic contrast acquisitions, and image subtractions.

Duke Scholars

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

December 1995

Volume

34

Issue

6

Start / End Page

905 / 909

Location

United States

Related Subject Headings

  • Signal Processing, Computer-Assisted
  • Respiration
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Image Processing, Computer-Assisted
  • Image Enhancement
  • Humans
  • Artifacts
  • Abdomen
  • 4003 Biomedical engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Feinberg, D. A., Rofsky, N. M., & Johnson, G. (1995). Multiple breath-hold averaging (MBA) method for increased SNR in abdominal MRI. Magn Reson Med, 34(6), 905–909. https://doi.org/10.1002/mrm.1910340617
Feinberg, D. A., N. M. Rofsky, and G. Johnson. “Multiple breath-hold averaging (MBA) method for increased SNR in abdominal MRI.Magn Reson Med 34, no. 6 (December 1995): 905–9. https://doi.org/10.1002/mrm.1910340617.
Feinberg DA, Rofsky NM, Johnson G. Multiple breath-hold averaging (MBA) method for increased SNR in abdominal MRI. Magn Reson Med. 1995 Dec;34(6):905–9.
Feinberg, D. A., et al. “Multiple breath-hold averaging (MBA) method for increased SNR in abdominal MRI.Magn Reson Med, vol. 34, no. 6, Dec. 1995, pp. 905–09. Pubmed, doi:10.1002/mrm.1910340617.
Feinberg DA, Rofsky NM, Johnson G. Multiple breath-hold averaging (MBA) method for increased SNR in abdominal MRI. Magn Reson Med. 1995 Dec;34(6):905–909.
Journal cover image

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

December 1995

Volume

34

Issue

6

Start / End Page

905 / 909

Location

United States

Related Subject Headings

  • Signal Processing, Computer-Assisted
  • Respiration
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Image Processing, Computer-Assisted
  • Image Enhancement
  • Humans
  • Artifacts
  • Abdomen
  • 4003 Biomedical engineering