Multiple breath-hold averaging (MBA) method for increased SNR in abdominal MRI.
Publication
, Journal Article
Feinberg, DA; Rofsky, NM; Johnson, G
Published in: Magn Reson Med
December 1995
Breath-holding during MR imaging eliminates respiratory motion artifacts but places a major time constraint on data acquisition. This constraint limits image signal-to-noise ratio and hence spatial resolution. A new method, multiple breath-hold averaging, is presented that overcomes these time limitations. Several images are acquired in sequential breath-hold periods, separated by periods of normal breathing, and averaged. This averaged image shows the expected increase in SNR with surprisingly little blurring due to misregistration. SNR improvements can be traded for increased spatial resolution. The MBA methodology can also be applied to 3D data acquisitions, dynamic contrast acquisitions, and image subtractions.
Duke Scholars
Published In
Magn Reson Med
DOI
ISSN
0740-3194
Publication Date
December 1995
Volume
34
Issue
6
Start / End Page
905 / 909
Location
United States
Related Subject Headings
- Signal Processing, Computer-Assisted
- Respiration
- Nuclear Medicine & Medical Imaging
- Magnetic Resonance Imaging
- Image Processing, Computer-Assisted
- Image Enhancement
- Humans
- Artifacts
- Abdomen
- 4003 Biomedical engineering
Citation
APA
Chicago
ICMJE
MLA
NLM
Feinberg, D. A., Rofsky, N. M., & Johnson, G. (1995). Multiple breath-hold averaging (MBA) method for increased SNR in abdominal MRI. Magn Reson Med, 34(6), 905–909. https://doi.org/10.1002/mrm.1910340617
Feinberg, D. A., N. M. Rofsky, and G. Johnson. “Multiple breath-hold averaging (MBA) method for increased SNR in abdominal MRI.” Magn Reson Med 34, no. 6 (December 1995): 905–9. https://doi.org/10.1002/mrm.1910340617.
Feinberg DA, Rofsky NM, Johnson G. Multiple breath-hold averaging (MBA) method for increased SNR in abdominal MRI. Magn Reson Med. 1995 Dec;34(6):905–9.
Feinberg, D. A., et al. “Multiple breath-hold averaging (MBA) method for increased SNR in abdominal MRI.” Magn Reson Med, vol. 34, no. 6, Dec. 1995, pp. 905–09. Pubmed, doi:10.1002/mrm.1910340617.
Feinberg DA, Rofsky NM, Johnson G. Multiple breath-hold averaging (MBA) method for increased SNR in abdominal MRI. Magn Reson Med. 1995 Dec;34(6):905–909.
Published In
Magn Reson Med
DOI
ISSN
0740-3194
Publication Date
December 1995
Volume
34
Issue
6
Start / End Page
905 / 909
Location
United States
Related Subject Headings
- Signal Processing, Computer-Assisted
- Respiration
- Nuclear Medicine & Medical Imaging
- Magnetic Resonance Imaging
- Image Processing, Computer-Assisted
- Image Enhancement
- Humans
- Artifacts
- Abdomen
- 4003 Biomedical engineering