Skip to main content
Journal cover image

Duplex Sonography in the Evaluation of Pancreas Transplants

Publication ,  Journal Article
Newberry, LB; Nelson, RC
Published in: Journal of Diagnostic Medical Sonography
January 1, 1991

Multiple allograft duplex sonographic examinations were performed on six patients who underwent pancreas transplantation to determine the role of this imaging modality. Poor correlation was found between gland size, parenchymal echogenicity or resistive index, and either rejection and/or cyclosporine toxicity. The pancreatic duct was not dilated on any of the examinations. Seven peripancreatic fluid collections were noted but were generally small. In one patient, no Doppler frequency shifts were found in spite of extensive interrogation of the parenchyma and subsequent biopsy confirmed allograft infarction. Duplex sonography appears most useful for excluding ductal dilatation, for detecting peripancreatic fluid collections, and for identifying infarction. © 1991, J.B. Lippincott Company. All rights reserved.

Duke Scholars

Published In

Journal of Diagnostic Medical Sonography

DOI

EISSN

1552-5430

ISSN

8756-4793

Publication Date

January 1, 1991

Volume

7

Issue

2

Start / End Page

74 / 80

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Newberry, L. B., & Nelson, R. C. (1991). Duplex Sonography in the Evaluation of Pancreas Transplants. Journal of Diagnostic Medical Sonography, 7(2), 74–80. https://doi.org/10.1177/875647939100700204
Newberry, L. B., and R. C. Nelson. “Duplex Sonography in the Evaluation of Pancreas Transplants.” Journal of Diagnostic Medical Sonography 7, no. 2 (January 1, 1991): 74–80. https://doi.org/10.1177/875647939100700204.
Newberry LB, Nelson RC. Duplex Sonography in the Evaluation of Pancreas Transplants. Journal of Diagnostic Medical Sonography. 1991 Jan 1;7(2):74–80.
Newberry, L. B., and R. C. Nelson. “Duplex Sonography in the Evaluation of Pancreas Transplants.” Journal of Diagnostic Medical Sonography, vol. 7, no. 2, Jan. 1991, pp. 74–80. Scopus, doi:10.1177/875647939100700204.
Newberry LB, Nelson RC. Duplex Sonography in the Evaluation of Pancreas Transplants. Journal of Diagnostic Medical Sonography. 1991 Jan 1;7(2):74–80.
Journal cover image

Published In

Journal of Diagnostic Medical Sonography

DOI

EISSN

1552-5430

ISSN

8756-4793

Publication Date

January 1, 1991

Volume

7

Issue

2

Start / End Page

74 / 80

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 1103 Clinical Sciences