Skip to main content

MTF and NPS study of high-resolution LCDs and CRTs for mammography

Publication ,  Journal Article
Poolla, A; Suri, JS; Samei, E; Pisano, ED; Minyard, T; Woodward, R; Schleupen, KR; Wright, S; Coley, S; Janer, R
Published in: Digest of Technical Papers - SID International Symposium
December 1, 2005

This paper presents a closer look on the link between the physical parameters (MTF and NPS) that characterize the performance of a liquid crystal display (LCD) and the architecture that generates the images. Understanding the major architectural difference between the cathode ray tube (CRT) and LCD displays can lead to better image quality analysis and characterization of the LCD displays. The aim of this research is to quantify two major image quality control parameters namely, modulation transfer function (MTF) and noise power spectrum (NPS) and understand their significance with respect to the architecture of the LCD and CRT displays. The experimentation was performed at Fischer Imaging Corporation research and development division in Denver, CO. We conclude the following: (1) The MTF of LCD is higher than that of CRT, and (2) LCD has higher NPS. The results thus infer that the LCD is better suitable display compared to CRT displays for mammography applications particularly considering its superior resolution. © 2005 SID.

Duke Scholars

Published In

Digest of Technical Papers - SID International Symposium

DOI

ISSN

0097-966X

Publication Date

December 1, 2005

Volume

36

Issue

1

Start / End Page

196 / 199
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Poolla, A., Suri, J. S., Samei, E., Pisano, E. D., Minyard, T., Woodward, R., … Janer, R. (2005). MTF and NPS study of high-resolution LCDs and CRTs for mammography. Digest of Technical Papers - SID International Symposium, 36(1), 196–199. https://doi.org/10.1889/1.2036402
Poolla, A., J. S. Suri, E. Samei, E. D. Pisano, T. Minyard, R. Woodward, K. R. Schleupen, S. Wright, S. Coley, and R. Janer. “MTF and NPS study of high-resolution LCDs and CRTs for mammography.” Digest of Technical Papers - SID International Symposium 36, no. 1 (December 1, 2005): 196–99. https://doi.org/10.1889/1.2036402.
Poolla A, Suri JS, Samei E, Pisano ED, Minyard T, Woodward R, et al. MTF and NPS study of high-resolution LCDs and CRTs for mammography. Digest of Technical Papers - SID International Symposium. 2005 Dec 1;36(1):196–9.
Poolla, A., et al. “MTF and NPS study of high-resolution LCDs and CRTs for mammography.” Digest of Technical Papers - SID International Symposium, vol. 36, no. 1, Dec. 2005, pp. 196–99. Scopus, doi:10.1889/1.2036402.
Poolla A, Suri JS, Samei E, Pisano ED, Minyard T, Woodward R, Schleupen KR, Wright S, Coley S, Janer R. MTF and NPS study of high-resolution LCDs and CRTs for mammography. Digest of Technical Papers - SID International Symposium. 2005 Dec 1;36(1):196–199.

Published In

Digest of Technical Papers - SID International Symposium

DOI

ISSN

0097-966X

Publication Date

December 1, 2005

Volume

36

Issue

1

Start / End Page

196 / 199