Skip to main content
Journal cover image

Implementation of graphic user interface screen capture solution for workflow assessment of abdominal MR examinations valuable tool to analyze discrepancies in expected and experienced MR table time.

Publication ,  Journal Article
Roth, CJ; Boll, DT; Chea, YW; Wall, LK; Merkle, EM
Published in: Acad Radiol
October 2009

RATIONALE AND OBJECTIVES: The aim of this study was to assess if graphical user interface screen-capture software applied to a magnetic resonance (MR) hardware console could nonintrusively allow the analysis of discrepancies between expected and experienced MR table time. MATERIALS AND METHODS: Individual MR examination acquisition processes were captured in audio-video interleave streams for 10 patients who underwent comprehensive liver MR imaging. These audio-video streams were dissected into periods of true image data acquisition, scanner activity without direct image data acquisition, and scanner inactivity. RESULTS: Total expected time required for standardized liver MR image acquisition was estimated at 15 minutes. Experienced table times varied highly, ranging from 19:00 to 58:08 minutes. Image data acquisition occurred during approximately 58% (range, 43.3%-73.7%) of overall table time. Image data were obtained approximately 77% (range, 65.6%-87.0%) of the time the scanner spent active. CONCLUSION: Graphical user interface screen-capture software installed on an MR console nonintrusively revealed significant periods of table time spent not obtaining true image data and explained discrepancies between expected and experienced MR table times. Table-time calculations using Digital Imaging and Communications in Medicine image headers and scanner-logged time stamps are underestimations of true table time because they do not take into account some scanner activities not directly leading to image formation.

Duke Scholars

Published In

Acad Radiol

DOI

EISSN

1878-4046

Publication Date

October 2009

Volume

16

Issue

10

Start / End Page

1286 / 1291

Location

United States

Related Subject Headings

  • Young Adult
  • Workload
  • Software
  • Professional Competence
  • Observer Variation
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Magnetic Resonance Imaging
  • Liver
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Roth, C. J., Boll, D. T., Chea, Y. W., Wall, L. K., & Merkle, E. M. (2009). Implementation of graphic user interface screen capture solution for workflow assessment of abdominal MR examinations valuable tool to analyze discrepancies in expected and experienced MR table time. Acad Radiol, 16(10), 1286–1291. https://doi.org/10.1016/j.acra.2009.05.009
Roth, Christopher J., Daniel T. Boll, Yen W. Chea, Lisa K. Wall, and Elmar M. Merkle. “Implementation of graphic user interface screen capture solution for workflow assessment of abdominal MR examinations valuable tool to analyze discrepancies in expected and experienced MR table time.Acad Radiol 16, no. 10 (October 2009): 1286–91. https://doi.org/10.1016/j.acra.2009.05.009.
Journal cover image

Published In

Acad Radiol

DOI

EISSN

1878-4046

Publication Date

October 2009

Volume

16

Issue

10

Start / End Page

1286 / 1291

Location

United States

Related Subject Headings

  • Young Adult
  • Workload
  • Software
  • Professional Competence
  • Observer Variation
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Magnetic Resonance Imaging
  • Liver