Skip to main content
Journal cover image

Radionuclide ventricular function analysis.

Publication ,  Journal Article
Borges-Neto, S; Coleman, RE
Published in: Radiol Clin North Am
July 1993

The information available from ventricular function studies is important in the management of patients with cardiovascular disease. Radionuclide measurements of ventricular function are closely related to the presence and extent of myocardial damage secondary to various etiologies. The two most commonly used techniques to assess ventricular function are the first-pass radionuclide angiocardiogram and the equilibrium radionuclide angiogram. The first-pass radionuclide angiocardiographic technique assesses function at the time of the bolus administration of the radiotracer. The cardiac blood pool imaging technique has the advantage of being able to assess function hours after tracer administration. Both techniques have their own limitations and advantages. Several measurements can be obtained with radionuclide ventricular function analysis. The most important parameters obtained are the right and left ventricular EFs, wall motion analysis, intracardiac shunts, volumes, and diastolic function. Radionuclide ventricular function analysis can provide information beneficial to patient management in a variety of cardiac disorders including ischemic heart disease, valvular heart disease, and congenital heart disease. Radionuclide ventricular function measurements are well established, important determinants in patients with diagnosis and prognosis of cardiovascular disorders. New 99mTc-labeled radiopharmaceuticals are now available and permit the simultaneous measurement of myocardial perfusion and ventricular function. The combined perfusion and function studies obtained during a single tracer administration provide a large amount of information important to the management of patients with cardiovascular disease. The combination of perfusion and functional measurements may improve the prognostic evaluation of patients with cardiovascular disease.

Duke Scholars

Published In

Radiol Clin North Am

ISSN

0033-8389

Publication Date

July 1993

Volume

31

Issue

4

Start / End Page

817 / 830

Location

United States

Related Subject Headings

  • Ventricular Function
  • Technetium
  • Radionuclide Ventriculography
  • Nuclear Medicine & Medical Imaging
  • Humans
  • Heart Diseases
  • Coronary Circulation
  • 3203 Dentistry
  • 3202 Clinical sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Borges-Neto, S., & Coleman, R. E. (1993). Radionuclide ventricular function analysis. Radiol Clin North Am, 31(4), 817–830.
Borges-Neto, S., and R. E. Coleman. “Radionuclide ventricular function analysis.Radiol Clin North Am 31, no. 4 (July 1993): 817–30.
Borges-Neto S, Coleman RE. Radionuclide ventricular function analysis. Radiol Clin North Am. 1993 Jul;31(4):817–30.
Borges-Neto, S., and R. E. Coleman. “Radionuclide ventricular function analysis.Radiol Clin North Am, vol. 31, no. 4, July 1993, pp. 817–30.
Borges-Neto S, Coleman RE. Radionuclide ventricular function analysis. Radiol Clin North Am. 1993 Jul;31(4):817–830.
Journal cover image

Published In

Radiol Clin North Am

ISSN

0033-8389

Publication Date

July 1993

Volume

31

Issue

4

Start / End Page

817 / 830

Location

United States

Related Subject Headings

  • Ventricular Function
  • Technetium
  • Radionuclide Ventriculography
  • Nuclear Medicine & Medical Imaging
  • Humans
  • Heart Diseases
  • Coronary Circulation
  • 3203 Dentistry
  • 3202 Clinical sciences
  • 1103 Clinical Sciences