Skip to main content

Custom annular photodetector arrays for breast cancer margin assessment using diffuse reflectance spectroscopy

Publication ,  Journal Article
Dhar, S; Lo, JY; Yu, B; Brooke, MA; Ramanujam, N; Jokerst, NM
Published in: 2011 IEEE Biomedical Circuits and Systems Conference, BioCAS 2011
December 1, 2011

A custom imaging array has been optimized for diffuse reflectance spectroscopy for breast cancer margin assessment. The imaging array has been designed, fabricated and tested with a 99% diffuse reflectance standard, a 2% diffuse reflectance standard, bovine muscle tissue, and poultry tissue. Estimated signal-to-noise ratios of greater than 35 dB have been measured with all four specimens. Reflectance contrast image maps have been extracted from the diffuse reflectance signals for the poultry tissue and correlate well with the tissue sample. © 2011 IEEE.

Duke Scholars

Published In

2011 IEEE Biomedical Circuits and Systems Conference, BioCAS 2011

DOI

Publication Date

December 1, 2011

Start / End Page

440 / 443
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Dhar, S., Lo, J. Y., Yu, B., Brooke, M. A., Ramanujam, N., & Jokerst, N. M. (2011). Custom annular photodetector arrays for breast cancer margin assessment using diffuse reflectance spectroscopy. 2011 IEEE Biomedical Circuits and Systems Conference, BioCAS 2011, 440–443. https://doi.org/10.1109/BioCAS.2011.6107822
Dhar, S., J. Y. Lo, B. Yu, M. A. Brooke, N. Ramanujam, and N. M. Jokerst. “Custom annular photodetector arrays for breast cancer margin assessment using diffuse reflectance spectroscopy.” 2011 IEEE Biomedical Circuits and Systems Conference, BioCAS 2011, December 1, 2011, 440–43. https://doi.org/10.1109/BioCAS.2011.6107822.
Dhar S, Lo JY, Yu B, Brooke MA, Ramanujam N, Jokerst NM. Custom annular photodetector arrays for breast cancer margin assessment using diffuse reflectance spectroscopy. 2011 IEEE Biomedical Circuits and Systems Conference, BioCAS 2011. 2011 Dec 1;440–3.
Dhar, S., et al. “Custom annular photodetector arrays for breast cancer margin assessment using diffuse reflectance spectroscopy.” 2011 IEEE Biomedical Circuits and Systems Conference, BioCAS 2011, Dec. 2011, pp. 440–43. Scopus, doi:10.1109/BioCAS.2011.6107822.
Dhar S, Lo JY, Yu B, Brooke MA, Ramanujam N, Jokerst NM. Custom annular photodetector arrays for breast cancer margin assessment using diffuse reflectance spectroscopy. 2011 IEEE Biomedical Circuits and Systems Conference, BioCAS 2011. 2011 Dec 1;440–443.

Published In

2011 IEEE Biomedical Circuits and Systems Conference, BioCAS 2011

DOI

Publication Date

December 1, 2011

Start / End Page

440 / 443