Skip to main content

-Measurement of the proton's electric to magnetic form factor ratio from 1H(over -->)(e(over -->),e'p).

Publication ,  Journal Article
Crawford, CB; Sindile, A; Akdogan, T; Alarcon, R; Bertozzi, W; Booth, E; Botto, T; Calarco, J; Clasie, B; Degrush, A; Donnelly, TW; Dow, K ...
Published in: Physical review letters
February 2007

We report the first precision measurement of the proton electric to magnetic form factor ratio from spin-dependent elastic scattering of longitudinally polarized electrons from a polarized hydrogen internal gas target. The measurement was performed at the MIT-Bates South Hall Ring over a range of four-momentum transfer squared Q2 from 0.15 to 0.65 (GeV/c)(2). Significantly improved results on the proton electric and magnetic form factors are obtained in combination with existing cross-section data on elastic electron-proton scattering in the same Q2 region.

Duke Scholars

Published In

Physical review letters

DOI

EISSN

1079-7114

ISSN

0031-9007

Publication Date

February 2007

Volume

98

Issue

5

Start / End Page

052301

Related Subject Headings

  • General Physics
  • 51 Physical sciences
  • 49 Mathematical sciences
  • 40 Engineering
  • 09 Engineering
  • 02 Physical Sciences
  • 01 Mathematical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Crawford, C. B., Sindile, A., Akdogan, T., Alarcon, R., Bertozzi, W., Booth, E., … Zwart, T. (2007). -Measurement of the proton's electric to magnetic form factor ratio from 1H(over -->)(e(over -->),e'p). Physical Review Letters, 98(5), 052301. https://doi.org/10.1103/physrevlett.98.052301
Crawford, C. B., A. Sindile, T. Akdogan, R. Alarcon, W. Bertozzi, E. Booth, T. Botto, et al. “-Measurement of the proton's electric to magnetic form factor ratio from 1H(over -->)(e(over -->),e'p).Physical Review Letters 98, no. 5 (February 2007): 052301. https://doi.org/10.1103/physrevlett.98.052301.
Crawford CB, Sindile A, Akdogan T, Alarcon R, Bertozzi W, Booth E, et al. -Measurement of the proton's electric to magnetic form factor ratio from 1H(over -->)(e(over -->),e'p). Physical review letters. 2007 Feb;98(5):052301.
Crawford, C. B., et al. “-Measurement of the proton's electric to magnetic form factor ratio from 1H(over -->)(e(over -->),e'p).Physical Review Letters, vol. 98, no. 5, Feb. 2007, p. 052301. Epmc, doi:10.1103/physrevlett.98.052301.
Crawford CB, Sindile A, Akdogan T, Alarcon R, Bertozzi W, Booth E, Botto T, Calarco J, Clasie B, Degrush A, Donnelly TW, Dow K, Dutta D, Farkhondeh M, Fatemi R, Filoti O, Franklin W, Gao H, Geis E, Gilad S, Haeberli W, Hasell D, Hersman W, Holtrop M, Karpius P, Kohl M, Kolster H, Lee T, Maschinot A, Matthews J, McIlhany K, Meitanis N, Milner RG, Redwine RP, Seely J, Shinozaki A, Sirca S, Six E, Smith T, Tonguc B, Tschalaer C, Tsentalovich E, Turchinetz W, van den Brand JFJ, van der Laan J, Wang F, Wise T, Xiao Y, Xu W, Zhang C, Zhou Z, Ziskin V, Zwart T. -Measurement of the proton's electric to magnetic form factor ratio from 1H(over -->)(e(over -->),e'p). Physical review letters. 2007 Feb;98(5):052301.

Published In

Physical review letters

DOI

EISSN

1079-7114

ISSN

0031-9007

Publication Date

February 2007

Volume

98

Issue

5

Start / End Page

052301

Related Subject Headings

  • General Physics
  • 51 Physical sciences
  • 49 Mathematical sciences
  • 40 Engineering
  • 09 Engineering
  • 02 Physical Sciences
  • 01 Mathematical Sciences