Skip to main content

The Vitek analyser for routine bacterial identification and susceptibility testing: protocols, problems, and pitfalls.

Publication ,  Journal Article
Shetty, N; Hill, G; Ridgway, GL
Published in: J Clin Pathol
April 1998

Automated and semiautomated technology in microbiology has seen great advances in recent years. The choice of automated equipment for the identification and susceptibility testing of bacteria in a routine diagnostic laboratory depends on speed, accuracy, ease of use, and cost factors. The Vitek analyser (bioMerieux, UK) was installed in a busy diagnostic teaching hospital laboratory in London. This report describes one year's experience. Changes to work practice as a result of incorporating the equipment into the laboratory, and the advantages and disadvantages of automation in key areas are described in detail, together with possible solutions to problems. The Vitek analyser was found to be valuable for the speed and accuracy with which results were available for the common bacterial pathogens. Results of susceptibility testing were standardised according to NCCLS guidelines and used breakpoint MICs to ascertain susceptibility and resistance; they were an improvement on disc testing. This equipment is not a reference facility for difficult to identify organisms and many manual techniques, including some disc susceptibility testing, will have to be retained by the laboratory.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Clin Pathol

DOI

ISSN

0021-9746

Publication Date

April 1998

Volume

51

Issue

4

Start / End Page

316 / 323

Location

England

Related Subject Headings

  • Reagent Strips
  • Pathology
  • Microbial Sensitivity Tests
  • Humans
  • Gram-Positive Bacteria
  • Gram-Negative Bacteria
  • Expert Systems
  • Clinical Protocols
  • Bacteriuria
  • Bacterial Typing Techniques
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Shetty, N., Hill, G., & Ridgway, G. L. (1998). The Vitek analyser for routine bacterial identification and susceptibility testing: protocols, problems, and pitfalls. J Clin Pathol, 51(4), 316–323. https://doi.org/10.1136/jcp.51.4.316
Shetty, N., G. Hill, and G. L. Ridgway. “The Vitek analyser for routine bacterial identification and susceptibility testing: protocols, problems, and pitfalls.J Clin Pathol 51, no. 4 (April 1998): 316–23. https://doi.org/10.1136/jcp.51.4.316.
Shetty, N., et al. “The Vitek analyser for routine bacterial identification and susceptibility testing: protocols, problems, and pitfalls.J Clin Pathol, vol. 51, no. 4, Apr. 1998, pp. 316–23. Pubmed, doi:10.1136/jcp.51.4.316.

Published In

J Clin Pathol

DOI

ISSN

0021-9746

Publication Date

April 1998

Volume

51

Issue

4

Start / End Page

316 / 323

Location

England

Related Subject Headings

  • Reagent Strips
  • Pathology
  • Microbial Sensitivity Tests
  • Humans
  • Gram-Positive Bacteria
  • Gram-Negative Bacteria
  • Expert Systems
  • Clinical Protocols
  • Bacteriuria
  • Bacterial Typing Techniques