It is shown that with mapping it is possible to sample organelles (here, mitochondrial) more thoroughly than is realistically possible in static raster probes. It is possible to obtain content measurements from a single pixel, several pixels, or the entire mitochondrion. When the elemental contents of the regions are compared with the contents of mapped whole mitochondria, no differences are found. The whole mitochondria value was obtained by outlining the entire mitochondrion. The sodium response to reversal of the sodium gradient follows the same trend as in the quantitative values reported previously for cultured heart cells and rabbit papillary muscles.
Duke Scholars
Published In
Proceedings, Annual Conference - Microbeam Analysis Society
ISSN
0278-1727
Publication Date
December 1, 1990
Start / End Page
387 / 389
Related Subject Headings
- Microscopy
- 0912 Materials Engineering
- 0601 Biochemistry and Cell Biology
- 0204 Condensed Matter Physics
Citation
APA
Chicago
ICMJE
MLA
NLM
Carney, M., LeFurgey, A., Hawkey, L. A., Ingram, P., & Lieberman, M. (1990). Comparison of quantitative x-ray imaging and raster probing in heart cells exposed to sodium-free media. Proceedings, Annual Conference - Microbeam Analysis Society, 387–389.
Carney, M., A. LeFurgey, L. A. Hawkey, P. Ingram, and M. Lieberman. “Comparison of quantitative x-ray imaging and raster probing in heart cells exposed to sodium-free media.” Proceedings, Annual Conference - Microbeam Analysis Society, December 1, 1990, 387–89.
Carney M, LeFurgey A, Hawkey LA, Ingram P, Lieberman M. Comparison of quantitative x-ray imaging and raster probing in heart cells exposed to sodium-free media. Proceedings, Annual Conference - Microbeam Analysis Society. 1990 Dec 1;387–9.
Carney, M., et al. “Comparison of quantitative x-ray imaging and raster probing in heart cells exposed to sodium-free media.” Proceedings, Annual Conference - Microbeam Analysis Society, Dec. 1990, pp. 387–89.
Carney M, LeFurgey A, Hawkey LA, Ingram P, Lieberman M. Comparison of quantitative x-ray imaging and raster probing in heart cells exposed to sodium-free media. Proceedings, Annual Conference - Microbeam Analysis Society. 1990 Dec 1;387–389.
Published In
Proceedings, Annual Conference - Microbeam Analysis Society
ISSN
0278-1727
Publication Date
December 1, 1990
Start / End Page
387 / 389
Related Subject Headings
- Microscopy
- 0912 Materials Engineering
- 0601 Biochemistry and Cell Biology
- 0204 Condensed Matter Physics