Skip to main content

Estimating surface radiation dose from Multidetector CT: Cylindrical phantoms, Anthropomorphic phantoms and Monte Carlo Simulations

Publication ,  Journal Article
DeMarco, JJ; Cagnon, CH; Cody, DD; Stevens, DM; McCollough, CH; O'Daniel, J; McNitt-Gray, MF
Published in: Progress in Biomedical Optics and Imaging Proceedings of SPIE
August 25, 2005

Multidetector CT (MDCT) systems offer larger coverage and wider z-axis beams, resulting in larger cone angles. One impact on radiation dose is that while radiation profiles at isocenter are constant when contiguous axial scans are performed, the increased beam divergence from the larger cone angle results in significant surface dose variation. The purpose of this work was to measure the magnitude of this effect. Contiguous axial scans were acquired using an MDCT for two sizes of cylindrical phantoms and an anthropomorphic phantom. Film dosimetry and/or radiation detector measurements were performed on the surface of each phantom. Detailed mathematical models were developed for the MDCT scanner and all phantoms. Monte Carlo simulations of contiguous axial scans were performed for each phantom model. From cylindrical phantoms, film dosimetry at the surface showed differences between peak and valley that reached 50%. From the anthropomorphic phantom, measured values ranged from 7.9 to 16.2 mGy at the phantom surface. Monte Carlo simulations demonstrated these variations in both cylindrical and anthropomorphic phantoms. The magnitude of variation was also related to object size. Even when contiguous axial scans are performed on MDCT, surface radiation profiles show considerable variation. This variation will increase as MDCT cone angles increase and when non-contiguous scans (e.g. pitch > 1) are acquired. The variation is also a function of object size. While average surface doses may remain constant, peak doses may increase, which may be significant for radiation sensitive organs at or near the surface (e.g. breast, thyroid).

Duke Scholars

Published In

Progress in Biomedical Optics and Imaging Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

August 25, 2005

Volume

5745

Issue

I

Start / End Page

102 / 112
 

Citation

APA
Chicago
ICMJE
MLA
NLM
DeMarco, J. J., Cagnon, C. H., Cody, D. D., Stevens, D. M., McCollough, C. H., O’Daniel, J., & McNitt-Gray, M. F. (2005). Estimating surface radiation dose from Multidetector CT: Cylindrical phantoms, Anthropomorphic phantoms and Monte Carlo Simulations. Progress in Biomedical Optics and Imaging Proceedings of SPIE, 5745(I), 102–112. https://doi.org/10.1117/12.595933
DeMarco, J. J., C. H. Cagnon, D. D. Cody, D. M. Stevens, C. H. McCollough, J. O’Daniel, and M. F. McNitt-Gray. “Estimating surface radiation dose from Multidetector CT: Cylindrical phantoms, Anthropomorphic phantoms and Monte Carlo Simulations.” Progress in Biomedical Optics and Imaging Proceedings of SPIE 5745, no. I (August 25, 2005): 102–12. https://doi.org/10.1117/12.595933.
DeMarco JJ, Cagnon CH, Cody DD, Stevens DM, McCollough CH, O’Daniel J, et al. Estimating surface radiation dose from Multidetector CT: Cylindrical phantoms, Anthropomorphic phantoms and Monte Carlo Simulations. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2005 Aug 25;5745(I):102–12.
DeMarco, J. J., et al. “Estimating surface radiation dose from Multidetector CT: Cylindrical phantoms, Anthropomorphic phantoms and Monte Carlo Simulations.” Progress in Biomedical Optics and Imaging Proceedings of SPIE, vol. 5745, no. I, Aug. 2005, pp. 102–12. Scopus, doi:10.1117/12.595933.
DeMarco JJ, Cagnon CH, Cody DD, Stevens DM, McCollough CH, O’Daniel J, McNitt-Gray MF. Estimating surface radiation dose from Multidetector CT: Cylindrical phantoms, Anthropomorphic phantoms and Monte Carlo Simulations. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2005 Aug 25;5745(I):102–112.

Published In

Progress in Biomedical Optics and Imaging Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

August 25, 2005

Volume

5745

Issue

I

Start / End Page

102 / 112