Skip to main content
Journal cover image

Local drug delivery of argatroban from a polymeric-metallic composite stent reduces platelet deposition in a swine coronary model.

Journal articles  - Journal Article
Kruse, KR; Crowley, JJ; Tanguay, JF; Santos, RM; Millare, DS; Phillips, HR; Zidar, JP; Stack, RS
Published in: Catheter Cardiovasc Interv
April 1999

Thrombus formation after intracoronary stent implantation provides a stimulus for neointimal hyperplasia and if excessive can result in stent thrombosis. We tested the hypothesis that local delivery of an antithrombin drug from a polymeric-metallic stent inhibits platelet thrombus formation. An uncoated metal slotted tube, a jellyroll slotted metal stent with an Argatroban-loaded polymeric sleeve, and a jellyroll slotted metal stent with a drug-leached polymeric sleeve were randomly deployed into the coronary arteries of eight juvenile farm swine. Platelet deposition in the stented segments was determined at 2 hr using autologous 111Indium oxime-labeled platelets. Platelet deposition was significantly less in the Argatroban-loaded stents compared to the Argatroban-leached stents (1.40 x 10(8) platelets/cm2 vs. 26.8 x 10(8) platelets/cm2; P=0.005). When corrected for differences in the metal surface area exposed to blood, platelet deposition was significantly lower in the Argatroban-loaded stent (1.74+/-1.95 x 10(8)/cm2) compared to the Argatroban-leached stent (33.5+/-39.1 x 10(8)/cm2; P=0.005) and the uncoated metal stent (36.2+/-73.3 x 10(8)/cm2; P=0.006). In this coronary stent thrombosis model Argatroban has local antithrombotic properties when delivered with a polymer-metallic stent. Improved polymeric designs may reduce risk of thrombus deposition at the site of stent implantation.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Catheter Cardiovasc Interv

DOI

ISSN

1522-1946

Publication Date

April 1999

Volume

46

Issue

4

Start / End Page

503 / 507

Location

United States

Related Subject Headings

  • Swine
  • Sulfonamides
  • Stents
  • Random Allocation
  • Polymers
  • Pipecolic Acids
  • Metals
  • Indium Radioisotopes
  • Coronary Vessels
  • Coronary Thrombosis
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Kruse, K. R., Crowley, J. J., Tanguay, J. F., Santos, R. M., Millare, D. S., Phillips, H. R., … Stack, R. S. (1999). Local drug delivery of argatroban from a polymeric-metallic composite stent reduces platelet deposition in a swine coronary model. Catheter Cardiovasc Interv, 46(4), 503–507. https://doi.org/10.1002/(SICI)1522-726X(199904)46:4<503::AID-CCD25>3.0.CO;2-3
Kruse, K. R., J. J. Crowley, J. F. Tanguay, R. M. Santos, D. S. Millare, H. R. Phillips, J. P. Zidar, and R. S. Stack. “Local drug delivery of argatroban from a polymeric-metallic composite stent reduces platelet deposition in a swine coronary model.Catheter Cardiovasc Interv 46, no. 4 (April 1999): 503–7. https://doi.org/10.1002/(SICI)1522-726X(199904)46:4<503::AID-CCD25>3.0.CO;2-3.
Kruse KR, Crowley JJ, Tanguay JF, Santos RM, Millare DS, Phillips HR, et al. Local drug delivery of argatroban from a polymeric-metallic composite stent reduces platelet deposition in a swine coronary model. Catheter Cardiovasc Interv. 1999 Apr;46(4):503–7.
Kruse, K. R., et al. “Local drug delivery of argatroban from a polymeric-metallic composite stent reduces platelet deposition in a swine coronary model.Catheter Cardiovasc Interv, vol. 46, no. 4, Apr. 1999, pp. 503–07. Pubmed, doi:10.1002/(SICI)1522-726X(199904)46:4<503::AID-CCD25>3.0.CO;2-3.
Kruse KR, Crowley JJ, Tanguay JF, Santos RM, Millare DS, Phillips HR, Zidar JP, Stack RS. Local drug delivery of argatroban from a polymeric-metallic composite stent reduces platelet deposition in a swine coronary model. Catheter Cardiovasc Interv. 1999 Apr;46(4):503–507.
Journal cover image

Published In

Catheter Cardiovasc Interv

DOI

ISSN

1522-1946

Publication Date

April 1999

Volume

46

Issue

4

Start / End Page

503 / 507

Location

United States

Related Subject Headings

  • Swine
  • Sulfonamides
  • Stents
  • Random Allocation
  • Polymers
  • Pipecolic Acids
  • Metals
  • Indium Radioisotopes
  • Coronary Vessels
  • Coronary Thrombosis