Skip to main content

Analyzing the Effect of dose reduction on the detection of mammographic lesions using mathematical observer models

Publication ,  Journal Article
Chawla, AS; Saunders, R; Abbey, C; Delong, D; Samei, E
Published in: Progress in Biomedical Optics and Imaging - Proceedings of SPIE
June 22, 2006

The purpose of this study was to determine the effect of dose reduction on the detectability of breast lesions in mammograms. Mammograms with dose levels corresponding to 50% and 25% of the original clinically-relevant exposure levels were simulated. Detection of masses and microcalicifications embedded in these mammograms was analyzed by four mathematical observer models, namely, the Hotelling Observer, Non-prewhitening Matched Filter with Eye Filter (NPWE), and Laguerre-Gauss and Gabor Channelized Hotelling Observers. Performance was measured in terms of ROC curves and Area under ROC Curves (AUC) under Signal Known Exactly but Variable Tasks (SKEV) paradigm. Gabor Channelized Hotelling Observer predicted deterioration in detectability of benign masses. The other algorithmic observers, however, did not indicate statistically significant differences in the detectability of masses and microcalcifications with reduction in dose. Detection of microcalcifications was affected more than the detection of masses. Overall, the results indicate that there is a potential for reduction of radiation dose level in mammographic screening procedures without severely compromising the detectability of lesions.

Duke Scholars

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

June 22, 2006

Volume

6146
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chawla, A. S., Saunders, R., Abbey, C., Delong, D., & Samei, E. (2006). Analyzing the Effect of dose reduction on the detection of mammographic lesions using mathematical observer models. Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 6146. https://doi.org/10.1117/12.656378
Chawla, A. S., R. Saunders, C. Abbey, D. Delong, and E. Samei. “Analyzing the Effect of dose reduction on the detection of mammographic lesions using mathematical observer models.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE 6146 (June 22, 2006). https://doi.org/10.1117/12.656378.
Chawla AS, Saunders R, Abbey C, Delong D, Samei E. Analyzing the Effect of dose reduction on the detection of mammographic lesions using mathematical observer models. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2006 Jun 22;6146.
Chawla, A. S., et al. “Analyzing the Effect of dose reduction on the detection of mammographic lesions using mathematical observer models.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol. 6146, June 2006. Scopus, doi:10.1117/12.656378.
Chawla AS, Saunders R, Abbey C, Delong D, Samei E. Analyzing the Effect of dose reduction on the detection of mammographic lesions using mathematical observer models. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2006 Jun 22;6146.

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

June 22, 2006

Volume

6146