Skip to main content

Initial study of quasi-monochromatic X-ray beam performance for X-ray computed mammotomography

Publication ,  Journal Article
McKinley, RL; Tornai, MP; Samei, E; Bradshaw, ML
Published in: IEEE Nuclear Science Symposium Conference Record
December 1, 2003

We evaluate the feasibility, benefits, and operating parameters of a quasi-monochromatic beam for a newly developed X-ray cone beam computed mammotomography application. The value of a near monochromatic X-ray source for a fully 3D tomography application is the expected improved ability to separate tissues with very small differences in attenuation coefficients while maintaining dose level at or below existing dual view mammography. X-ray spectra were simulated for a range of tungsten tube potentials, K-edge filter materials, filter thicknesses, and a 12 cm uncompressed breast. The detector was modeled as a digital flat-panel CsI(Tl) detector. Figures of merit computed included: ratio of mean beam energy post-breast to pre-breast; ratio of measured lesion contrasts with and without filtering; and exposure efficiency (SNR 2/exposure). Initial experiments were performed with a commercially available X-ray tube/generator system, Ce foil filters, and plastic breast and lesion tissue-equivalent slabs. Simulation results showed that tube potentials of 50-70 kVp with filters of Zr=57-63 yielded quasi-monochromatic X-ray spectra with optimal FOMs. Initial experimental measurements with Ce foil filters corroborate simulation results. Simulations and initial experiments with one type of filter show that this approach can improve image quality while reducing exposure, and will be implemented in our multi-modality X-ray CT/SPECT computed mammotomography system.

Duke Scholars

Published In

IEEE Nuclear Science Symposium Conference Record

ISSN

1095-7863

Publication Date

December 1, 2003

Volume

4

Start / End Page

2999 / 3003
 

Citation

APA
Chicago
ICMJE
MLA
NLM
McKinley, R. L., Tornai, M. P., Samei, E., & Bradshaw, M. L. (2003). Initial study of quasi-monochromatic X-ray beam performance for X-ray computed mammotomography. IEEE Nuclear Science Symposium Conference Record, 4, 2999–3003.
McKinley, R. L., M. P. Tornai, E. Samei, and M. L. Bradshaw. “Initial study of quasi-monochromatic X-ray beam performance for X-ray computed mammotomography.” IEEE Nuclear Science Symposium Conference Record 4 (December 1, 2003): 2999–3003.
McKinley RL, Tornai MP, Samei E, Bradshaw ML. Initial study of quasi-monochromatic X-ray beam performance for X-ray computed mammotomography. IEEE Nuclear Science Symposium Conference Record. 2003 Dec 1;4:2999–3003.
McKinley, R. L., et al. “Initial study of quasi-monochromatic X-ray beam performance for X-ray computed mammotomography.” IEEE Nuclear Science Symposium Conference Record, vol. 4, Dec. 2003, pp. 2999–3003.
McKinley RL, Tornai MP, Samei E, Bradshaw ML. Initial study of quasi-monochromatic X-ray beam performance for X-ray computed mammotomography. IEEE Nuclear Science Symposium Conference Record. 2003 Dec 1;4:2999–3003.

Published In

IEEE Nuclear Science Symposium Conference Record

ISSN

1095-7863

Publication Date

December 1, 2003

Volume

4

Start / End Page

2999 / 3003