Long-term implantation of voltammetric oxidase/peroxide glucose sensors in the rat peritoneum.

Publication ,  Journal Article
Clark, LC; Noyes, LK; Spokane, RB; Sudan, R; Miller, ML
Published in: Methods Enzymol
1988

Methods for designing, fabricating, testing in vitro and in vivo, and improving chronically implantable oxidase/peroxide-type polarographic glucose sensors are described. Voltammetric means to evaluate oxygen supply to the sensor and to measure the nearby microcirculation with hydrogen washout techniques using the implanted glucose sensor are outlined. Because some peritoneally implanted sensors have, perhaps surprisingly, remained functional for months, such devices may prove with further development to be useful as the sensing components in artificial pancreatic beta cells for the control of diabetes.

Duke Scholars

Published In

Methods Enzymol

DOI

ISSN

0076-6879

Publication Date

1988

Volume

137

Start / End Page

68 / 89

Location

United States

Related Subject Headings

  • Rats, Inbred Strains
  • Rats
  • Polarography
  • Peritoneal Cavity
  • Oxygen Consumption
  • Indicators and Reagents
  • Glucose Oxidase
  • Glucose
  • Female
  • Enzymes, Immobilized
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Clark, L. C., Noyes, L. K., Spokane, R. B., Sudan, R., & Miller, M. L. (1988). Long-term implantation of voltammetric oxidase/peroxide glucose sensors in the rat peritoneum. Methods Enzymol, 137, 68–89. https://doi.org/10.1016/0076-6879(88)37008-4
Clark, L. C., L. K. Noyes, R. B. Spokane, R. Sudan, and M. L. Miller. “Long-term implantation of voltammetric oxidase/peroxide glucose sensors in the rat peritoneum.Methods Enzymol 137 (1988): 68–89. https://doi.org/10.1016/0076-6879(88)37008-4.
Clark LC, Noyes LK, Spokane RB, Sudan R, Miller ML. Long-term implantation of voltammetric oxidase/peroxide glucose sensors in the rat peritoneum. Methods Enzymol. 1988;137:68–89.
Clark, L. C., et al. “Long-term implantation of voltammetric oxidase/peroxide glucose sensors in the rat peritoneum.Methods Enzymol, vol. 137, 1988, pp. 68–89. Pubmed, doi:10.1016/0076-6879(88)37008-4.
Clark LC, Noyes LK, Spokane RB, Sudan R, Miller ML. Long-term implantation of voltammetric oxidase/peroxide glucose sensors in the rat peritoneum. Methods Enzymol. 1988;137:68–89.
Journal cover image

Published In

Methods Enzymol

DOI

ISSN

0076-6879

Publication Date

1988

Volume

137

Start / End Page

68 / 89

Location

United States

Related Subject Headings

  • Rats, Inbred Strains
  • Rats
  • Polarography
  • Peritoneal Cavity
  • Oxygen Consumption
  • Indicators and Reagents
  • Glucose Oxidase
  • Glucose
  • Female
  • Enzymes, Immobilized