3-D Contrast-detail analysis for dedicated emission mammotomography

Publication ,  Journal Article
Cutler, SJ; Perez, KL; Tornai, MP
Published in: IEEE Nuclear Science Symposium Conference Record
January 1, 2006

An observer based 3D contrast-detail study is performed in an effort to evaluate the limits of object detectability for a dedicated CZT-based SPECT mammotomography imaging system under various imaging conditions. A novel, geometric contrast-resolution phantom was developed that can be used for both positive ("hot") and negative contrasts ("cold"). The 3cm long fillable tubes are arranged in six sectors having equal inner diameters ranging from 1mm to 6mm with plastic wall thicknesses of <0.25mm, on a pitch of twice their inner diameters. Scans using simple circular trajectories are first obtained of the activity filled tubes in a uniform water filled cylinder, first with no background activity, and then varying the rod:background concentration ratios from 10:1 to 1:10. The rod phantom is then placed inside a non-uniformly shaped breast phantom and scans are again acquired using both simple and complex 3D trajectories for similarly varying contrasts. Scan times are adjusted to account for radioactive decay, and both low and high noise data is obtained. An iterative OSEM reconstruction algorithm is used to reconstruct the data. Images are evaluated by six independent readers, identifying smallest distinguishable rod for each concentration and experimental setup. Results indicate that, using the SPECT camera having 2.5mm intrinsic pixels, the mean detectable size was ∼3.1mm at 10:1 ratio, degrading to ∼5.5mm with the 2.5:1 concentration ratio. Furthermore, there was little statistically significant difference (p<0.05) between cylinder vs. breast, simple vs. complex trajectories, or whether the rods appeared hot (10:1) or cold (1:10), indicating that data acquisition with the mammotomography system is quite robust. © 2006 IEEE.

Published In

IEEE Nuclear Science Symposium Conference Record

DOI

ISSN

1095-7863

Publication Date

January 1, 2006

Volume

5

Start / End Page

2954 / 2958
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Cutler, S. J., Perez, K. L., & Tornai, M. P. (2006). 3-D Contrast-detail analysis for dedicated emission mammotomography. IEEE Nuclear Science Symposium Conference Record, 5, 2954–2958. https://doi.org/10.1109/NSSMIC.2006.356495
Cutler, S. J., K. L. Perez, and M. P. Tornai. “3-D Contrast-detail analysis for dedicated emission mammotomography.” IEEE Nuclear Science Symposium Conference Record 5 (January 1, 2006): 2954–58. https://doi.org/10.1109/NSSMIC.2006.356495.
Cutler SJ, Perez KL, Tornai MP. 3-D Contrast-detail analysis for dedicated emission mammotomography. IEEE Nuclear Science Symposium Conference Record. 2006 Jan 1;5:2954–8.
Cutler, S. J., et al. “3-D Contrast-detail analysis for dedicated emission mammotomography.” IEEE Nuclear Science Symposium Conference Record, vol. 5, Jan. 2006, pp. 2954–58. Scopus, doi:10.1109/NSSMIC.2006.356495.
Cutler SJ, Perez KL, Tornai MP. 3-D Contrast-detail analysis for dedicated emission mammotomography. IEEE Nuclear Science Symposium Conference Record. 2006 Jan 1;5:2954–2958.

Published In

IEEE Nuclear Science Symposium Conference Record

DOI

ISSN

1095-7863

Publication Date

January 1, 2006

Volume

5

Start / End Page

2954 / 2958