Skip to main content

A synthetic aperture study of aperture size in the presence of noise and in vivo clutter

Publication ,  Journal Article
Bottenus, N; Byram, BC; Trahey, GE
Published in: Progress in Biomedical Optics and Imaging - Proceedings of SPIE
June 5, 2013

Conventional wisdom in ultrasonic array design drives development towards larger arrays because of the inverse relationship between aperture size and resolution. We propose a method using synthetic aperture beamforming to study image quality as a function of aperture size in simulation, in a phantom and in vivo. A single data acquisition can be beamformed to produce matched images with a range of aperture sizes, even in the presence of target motion. In this framework we evaluate the reliability of typical image quality metrics - speckle signal-tonoise ratio, contrast and contrast-to-noise ratio - for use in in vivo studies. Phantom and simulation studies are in good agreement in that there exists a point of diminishing returns in image quality at larger aperture sizes. We demonstrate challenges in applying and interpreting these metrics in vivo, showing results in hypoechoic vasculature regions. We explore the use of speckle brightness to describe image quality in the presence of in vivo clutter and underlying tissue inhomogeneities. © 2013 SPIE.

Duke Scholars

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

June 5, 2013

Volume

8675
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Bottenus, N., Byram, B. C., & Trahey, G. E. (2013). A synthetic aperture study of aperture size in the presence of noise and in vivo clutter. Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 8675. https://doi.org/10.1117/12.2006981
Bottenus, N., B. C. Byram, and G. E. Trahey. “A synthetic aperture study of aperture size in the presence of noise and in vivo clutter.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE 8675 (June 5, 2013). https://doi.org/10.1117/12.2006981.
Bottenus N, Byram BC, Trahey GE. A synthetic aperture study of aperture size in the presence of noise and in vivo clutter. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2013 Jun 5;8675.
Bottenus, N., et al. “A synthetic aperture study of aperture size in the presence of noise and in vivo clutter.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol. 8675, June 2013. Scopus, doi:10.1117/12.2006981.
Bottenus N, Byram BC, Trahey GE. A synthetic aperture study of aperture size in the presence of noise and in vivo clutter. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2013 Jun 5;8675.

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

June 5, 2013

Volume

8675