Skip to main content
construction release_alert
Scholars@Duke will be undergoing maintenance April 11-15. Some features may be unavailable during this time.
cancel
Journal cover image

Implementation of automated reporting of estimated glomerular filtration rate among Veterans Affairs laboratories: a retrospective study.

Publication ,  Journal Article
Hall, RK; Wang, V; Jackson, GL; Hammill, BG; Maciejewski, ML; Yano, EM; Svetkey, LP; Patel, UD
Published in: BMC Med Inform Decis Mak
July 12, 2012

BACKGROUND: Automated reporting of estimated glomerular filtration rate (eGFR) is a recent advance in laboratory information technology (IT) that generates a measure of kidney function with chemistry laboratory results to aid early detection of chronic kidney disease (CKD). Because accurate diagnosis of CKD is critical to optimal medical decision-making, several clinical practice guidelines have recommended the use of automated eGFR reporting. Since its introduction, automated eGFR reporting has not been uniformly implemented by U. S. laboratories despite the growing prevalence of CKD. CKD is highly prevalent within the Veterans Health Administration (VHA), and implementation of automated eGFR reporting within this integrated healthcare system has the potential to improve care. In July 2004, the VHA adopted automated eGFR reporting through a system-wide mandate for software implementation by individual VHA laboratories. This study examines the timing of software implementation by individual VHA laboratories and factors associated with implementation. METHODS: We performed a retrospective observational study of laboratories in VHA facilities from July 2004 to September 2009. Using laboratory data, we identified the status of implementation of automated eGFR reporting for each facility and the time to actual implementation from the date the VHA adopted its policy for automated eGFR reporting. Using survey and administrative data, we assessed facility organizational characteristics associated with implementation of automated eGFR reporting via bivariate analyses. RESULTS: Of 104 VHA laboratories, 88% implemented automated eGFR reporting in existing laboratory IT systems by the end of the study period. Time to initial implementation ranged from 0.2 to 4.0 years with a median of 1.8 years. All VHA facilities with on-site dialysis units implemented the eGFR software (52%, p<0.001). Other organizational characteristics were not statistically significant. CONCLUSIONS: The VHA did not have uniform implementation of automated eGFR reporting across its facilities. Facility-level organizational characteristics were not associated with implementation, and this suggests that decisions for implementation of this software are not related to facility-level quality improvement measures. Additional studies on implementation of laboratory IT, such as automated eGFR reporting, could identify factors that are related to more timely implementation and lead to better healthcare delivery.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

BMC Med Inform Decis Mak

DOI

EISSN

1472-6947

Publication Date

July 12, 2012

Volume

12

Start / End Page

69

Location

England

Related Subject Headings

  • United States Department of Veterans Affairs
  • United States
  • Time Factors
  • Risk Assessment
  • Retrospective Studies
  • Renal Insufficiency, Chronic
  • Practice Patterns, Physicians'
  • Practice Guidelines as Topic
  • Medical Records Systems, Computerized
  • Medical Informatics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Hall, R. K., Wang, V., Jackson, G. L., Hammill, B. G., Maciejewski, M. L., Yano, E. M., … Patel, U. D. (2012). Implementation of automated reporting of estimated glomerular filtration rate among Veterans Affairs laboratories: a retrospective study. BMC Med Inform Decis Mak, 12, 69. https://doi.org/10.1186/1472-6947-12-69
Hall, Rasheeda K., Virginia Wang, George L. Jackson, Bradley G. Hammill, Matthew L. Maciejewski, Elizabeth M. Yano, Laura P. Svetkey, and Uptal D. Patel. “Implementation of automated reporting of estimated glomerular filtration rate among Veterans Affairs laboratories: a retrospective study.BMC Med Inform Decis Mak 12 (July 12, 2012): 69. https://doi.org/10.1186/1472-6947-12-69.
Hall RK, Wang V, Jackson GL, Hammill BG, Maciejewski ML, Yano EM, et al. Implementation of automated reporting of estimated glomerular filtration rate among Veterans Affairs laboratories: a retrospective study. BMC Med Inform Decis Mak. 2012 Jul 12;12:69.
Hall, Rasheeda K., et al. “Implementation of automated reporting of estimated glomerular filtration rate among Veterans Affairs laboratories: a retrospective study.BMC Med Inform Decis Mak, vol. 12, July 2012, p. 69. Pubmed, doi:10.1186/1472-6947-12-69.
Hall RK, Wang V, Jackson GL, Hammill BG, Maciejewski ML, Yano EM, Svetkey LP, Patel UD. Implementation of automated reporting of estimated glomerular filtration rate among Veterans Affairs laboratories: a retrospective study. BMC Med Inform Decis Mak. 2012 Jul 12;12:69.
Journal cover image

Published In

BMC Med Inform Decis Mak

DOI

EISSN

1472-6947

Publication Date

July 12, 2012

Volume

12

Start / End Page

69

Location

England

Related Subject Headings

  • United States Department of Veterans Affairs
  • United States
  • Time Factors
  • Risk Assessment
  • Retrospective Studies
  • Renal Insufficiency, Chronic
  • Practice Patterns, Physicians'
  • Practice Guidelines as Topic
  • Medical Records Systems, Computerized
  • Medical Informatics