Skip to main content

Comparison of the Hypoxia PET Tracer (18)F-EF5 to Immunohistochemical Marker EF5 in 3 Different Human Tumor Xenograft Models.

Publication ,  Journal Article
Chitneni, SK; Bida, GT; Zalutsky, MR; Dewhirst, MW
Published in: J Nucl Med
July 2014

UNLABELLED: The availability of (18)F-labeled and unlabeled 2-(2-nitro-1H-imidazol-1-yl)-N-(2,2,3,3,3-pentafluoropropyl)-acetamide (EF5) allows for a comparative assessment of tumor hypoxia by PET and immunohistochemistry; however, the combined use of these 2 approaches has not been fully assessed in vivo. The aim of this study was to evaluate (18)F-EF5 tumor uptake versus EF5 binding and hypoxia as determined from immunohistochemistry at both macroscopic and microregional levels. METHODS: Three tumor models-PC3, HCT116, and H460-were evaluated. Tumor-bearing animals were coinjected with (18)F-EF5 and EF5 (30 mg/kg), and PET imaging was performed at 2.5 h after injection. After PET imaging and 2 min after Hoechst 33342 injection, the tumors were excised and evaluated for (18)F-EF5 distribution by autoradiography and EF5 binding by immunohistochemistry. Additionally, the effects of nonradioactive EF5 (30 mg/kg) on the hypoxia-imaging characteristics of (18)F-EF5 were evaluated by comparing the PET data for H460 tumors with those from animals injected with (18)F-EF5 alone. RESULTS: The uptake of (18)F-EF5 in hypoxic tumor regions and the spatial relationship between (18)F-EF5 uptake and EF5 binding varied among tumors. H460 tumors showed higher tumor-to-muscle contrast in PET imaging; however, the distribution and uptake of the tracer was less specific for hypoxia in H460 than in HCT116 and PC3 tumors. Correlation analyses revealed that the highest spatial correlation between (18)F-EF5 uptake and EF5 binding was in PC3 tumors (r = 0.73 ± 0.02) followed by HCT116 (r = 0.60 ± 0.06) and H460 (r = 0.53 ± 0.10). Uptake and binding of (18)F-EF5 and EF5 correlated negatively with Hoechst 33342 perfusion marker distribution in the 3 tumor models. Image contrast and heterogeneous uptake of (18)F-EF5 in H460 tumors was significantly higher when the radiotracer was used alone versus in combination with unlabeled EF5 (tumor-to-muscle ratio of 2.51 ± 0.33 vs. 1.71 ± 0.17, P < 0.001). CONCLUSION: The uptake and hypoxia selectivity of (18)F-EF5 varied among tumor models when animals also received nonradioactive EF5. Combined use of radioactive and nonradioactive EF5 for independent assessment of tumor hypoxia by PET and immunohistochemistry methods is promising; however, the EF5 drug concentrations that are required for immunohistochemistry assays may affect the uptake of (18)F-EF5 in hypoxic cells in certain tumor types as observed in H460 in this study.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Nucl Med

DOI

EISSN

1535-5667

Publication Date

July 2014

Volume

55

Issue

7

Start / End Page

1192 / 1197

Location

United States

Related Subject Headings

  • Rats
  • Positron-Emission Tomography
  • Nuclear Medicine & Medical Imaging
  • Neoplasms
  • Mice
  • Immunohistochemistry
  • Hydrocarbons, Fluorinated
  • Humans
  • Fluorine Radioisotopes
  • Etanidazole
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chitneni, S. K., Bida, G. T., Zalutsky, M. R., & Dewhirst, M. W. (2014). Comparison of the Hypoxia PET Tracer (18)F-EF5 to Immunohistochemical Marker EF5 in 3 Different Human Tumor Xenograft Models. J Nucl Med, 55(7), 1192–1197. https://doi.org/10.2967/jnumed.114.137448
Chitneni, Satish K., Gerald T. Bida, Michael R. Zalutsky, and Mark W. Dewhirst. “Comparison of the Hypoxia PET Tracer (18)F-EF5 to Immunohistochemical Marker EF5 in 3 Different Human Tumor Xenograft Models.J Nucl Med 55, no. 7 (July 2014): 1192–97. https://doi.org/10.2967/jnumed.114.137448.
Chitneni SK, Bida GT, Zalutsky MR, Dewhirst MW. Comparison of the Hypoxia PET Tracer (18)F-EF5 to Immunohistochemical Marker EF5 in 3 Different Human Tumor Xenograft Models. J Nucl Med. 2014 Jul;55(7):1192–7.
Chitneni, Satish K., et al. “Comparison of the Hypoxia PET Tracer (18)F-EF5 to Immunohistochemical Marker EF5 in 3 Different Human Tumor Xenograft Models.J Nucl Med, vol. 55, no. 7, July 2014, pp. 1192–97. Pubmed, doi:10.2967/jnumed.114.137448.
Chitneni SK, Bida GT, Zalutsky MR, Dewhirst MW. Comparison of the Hypoxia PET Tracer (18)F-EF5 to Immunohistochemical Marker EF5 in 3 Different Human Tumor Xenograft Models. J Nucl Med. 2014 Jul;55(7):1192–1197.

Published In

J Nucl Med

DOI

EISSN

1535-5667

Publication Date

July 2014

Volume

55

Issue

7

Start / End Page

1192 / 1197

Location

United States

Related Subject Headings

  • Rats
  • Positron-Emission Tomography
  • Nuclear Medicine & Medical Imaging
  • Neoplasms
  • Mice
  • Immunohistochemistry
  • Hydrocarbons, Fluorinated
  • Humans
  • Fluorine Radioisotopes
  • Etanidazole