Skip to main content

RSNA/QIBA: Shear wave speed as a biomarker for liver fibrosis staging

Publication ,  Conference
Hall, TJ; Milkowski, A; Garra, B; Carson, P; Palmeri, M; Nightingale, K; Lynch, T; Alturki, A; Andre, M; Audiere, S; Bamber, J; Barr, R ...
Published in: IEEE International Ultrasonics Symposium, IUS
December 1, 2013

An interlaboratory study of shear wave speed (SWS) estimation was performed. Commercial shear wave elastography systems from Fibroscan, Philips, Siemens and Supersonic Imagine, as well as several custom laboratory systems, were involved. Fifteen sites were included in the study. CIRS manufactured and donated 11 pairs of custom phantoms designed for the purposes of this investigation. Dynamic mechanical tests of equivalent phantom materials were also performed. The results of this study demonstrate that there is very good agreement among SWS estimation systems, but there are several sources of bias and variance that can be addressed to improve consistency of measurement results. © 2013 IEEE.

Duke Scholars

Published In

IEEE International Ultrasonics Symposium, IUS

DOI

EISSN

1948-5727

ISSN

1948-5719

Publication Date

December 1, 2013

Start / End Page

397 / 400
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Hall, T. J., Milkowski, A., Garra, B., Carson, P., Palmeri, M., Nightingale, K., … Zhao, H. (2013). RSNA/QIBA: Shear wave speed as a biomarker for liver fibrosis staging. In IEEE International Ultrasonics Symposium, IUS (pp. 397–400). https://doi.org/10.1109/ULTSYM.2013.0103
Hall, T. J., A. Milkowski, B. Garra, P. Carson, M. Palmeri, K. Nightingale, T. Lynch, et al. “RSNA/QIBA: Shear wave speed as a biomarker for liver fibrosis staging.” In IEEE International Ultrasonics Symposium, IUS, 397–400, 2013. https://doi.org/10.1109/ULTSYM.2013.0103.
Hall TJ, Milkowski A, Garra B, Carson P, Palmeri M, Nightingale K, et al. RSNA/QIBA: Shear wave speed as a biomarker for liver fibrosis staging. In: IEEE International Ultrasonics Symposium, IUS. 2013. p. 397–400.
Hall, T. J., et al. “RSNA/QIBA: Shear wave speed as a biomarker for liver fibrosis staging.” IEEE International Ultrasonics Symposium, IUS, 2013, pp. 397–400. Scopus, doi:10.1109/ULTSYM.2013.0103.
Hall TJ, Milkowski A, Garra B, Carson P, Palmeri M, Nightingale K, Lynch T, Alturki A, Andre M, Audiere S, Bamber J, Barr R, Bercoff J, Bernal M, Brum J, Chan HW, Chen S, Cohen-Bacrie C, Couade M, Daniels A, Dewall R, Dillman J, Ehman R, Franchi-Abella S, Fromageau J, Gennisson JL, Henry JP, Ivancevich N, Kalin J, Kohn S, Kugel J, Lee K, Liu N, Loupas T, Mazernik J, McAleavey S, Miette V, Metz S, Morel B, Nelson T, Nordberg E, Oudry J, Padwal M, Rouze N, Samir A, Sandrin L, Schaccitti J, Schmitt C, Shamdasani V, Song P, Switalski P, Wang M, Wear K, Xie H, Zhao H. RSNA/QIBA: Shear wave speed as a biomarker for liver fibrosis staging. IEEE International Ultrasonics Symposium, IUS. 2013. p. 397–400.

Published In

IEEE International Ultrasonics Symposium, IUS

DOI

EISSN

1948-5727

ISSN

1948-5719

Publication Date

December 1, 2013

Start / End Page

397 / 400